According to the wording ,2 different phase wires "can" run through the same conduit.

Not only can they, but if they are part of the same circuit they must. And in cases where conductors are paralleled, meaning more than one conductor per phase as is common in commercial and industrial installations, you put one conductor of each phase and a neutral, if one exists, and a ground in each conduit. Not doing so, meaning to put all of one phase in one conduit, causes a voltage to be induced into the conduit and a tremendous amount of heat builds up. Even when using pvc or other non-metallic conduit, somewhere along the way you have something metallic and have the same problem.

To simplify, you must put all conductors associated with the same circuit in the same conduit.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Why 2 different phase wire are not supposed to pass through same conduit?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can you run different phases in the same conduit?

In the US, the National Electrical Code (NEC) will allow you to install single phase and three phase systems in the same conduit.


Can a three phase circuit be installed in the same conduit or in different conduits?

The conductors of any three phase circuit must be run in the same conduit. If the circuit requires a neutral, it must also run with the conductors in the same conduit. (If they were to be run in more than one conduit or raceway, the circuit would not operate properly.)


Is conduit necessary for single phase wiring?

yes


Why should phase and neutral wire be put together in the metal conduit?

to prevent live conduit in case of short circuit


Is a phase of the moon supposed to be capitalized?

Usually, yes a phase of the moon is supposed to be capitalized.


Can you run two 2 pole single phase circuits in the same conduit?

Yes, this only adds up to four wires. The wire sizing is dependant on the amperage of the two single phase loads. Remember to calculate the conduit fill of the four wires to make sure that you have the correct size conduit for the installation.


Can 3 phase power and single phase be ran in the same conduit?

Yes they can. There are regulations that cover most jurisdictions regarding how different cables can be contained. It is important that you are knowledgeable about your local requirements before starting the work.


What is the significance of the stationary phase in gas chromatography?

The stationary phase in gas chromatography is crucial because it interacts with the components of the sample being analyzed, causing them to either be retained or move at different rates through the column. This separation process allows for the identification and quantification of individual components in the sample mixture. The stationary phase can be tailored to enhance the separation efficiency based on the specific properties of the compounds being analyzed.


What is info on a 120V through its double 20A breaker and 10-2 plus a separate bare ground inside plastic flex conduit to a three-prong 240V outlet box?

So what's your question? 110V would be hot to neutral/ground. 220V is hot-to-hot (phase to phase).


What size conduit for 400amps?

The sizing of conduit systems that wire has to be pulled into is dependant on the physical size of the conductor being drawn into the conduit. The second governing factor is the conductor count of the specific conductor that is needed. A 500 MCM copper conductor with an insulation factor of 90 degrees C is rated at 430 amps. This is where the conductor count is need by the service, as to whether the service is single or three phase. In this specific case, the electrical code will allow both single and three phase installations to use the same size conduit. A maximum total of four 500 MCM conductors can be drawn into a 78 mm diameter conduit.


What is the acceptable insulation resistance megger reading of 160 linear feet of 350 MCM copper underground cable phase to phase phase to neutral and phase to ground?

Engineers that I have worked with state in their specifications that all meggered wires must have a reading of 5 Meg ohms or higher. If the reading is lower that this benchmark start checking splices especially if it is an underground installation. Water usually accumulates in underground conduit systems and when the wires are pulled in there is a certain amount of conductor scraping. This starts the downward spiral from infinity. Check termination points close to the exit point of the conduit. A certain amount of evaporation from the conduit condensates on the terminal points.


If very few cells are found in a certain phase of mitosis what does this indicate about the length of that phase?

If very few cells are found in a certain phase of mitosis, it may indicate that the length of that phase is short. Cells move through mitosis at different rates, and the duration of each phase can vary. Low cell numbers in a particular phase suggest that cells progress quickly through that phase.