Only the main panel is grounded directly because if you ground each junction box of subpanel ground loop current paths are possible that can cause shock hazards. The ground rod is connected to main panel and the neutral is bonded to that ground as is the ground wire. The neutral and ground wire are then run to all circuits, junction boxes and subpanels throughout the house.

If you tie neutral and ground together at any point in the house, other than the main panel ground loops can exist and cause shocks.

User Avatar

Wiki User

14y ago

Still curious? Ask our experts.

Chat with our AI personalities

LaoLao
The path is yours to walk; I am only here to hold up a mirror.
Chat with Lao
JordanJordan
Looking for a career mentor? I've seen my fair share of shake-ups.
Chat with Jordan
ProfessorProfessor
I will give you the most educated answer.
Chat with Professor

Add your answer:

Earn +20 pts
Q: Why isn't there a ground in a junction box?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

Do you need a junction box for each light fixture?

Can lights have a junction box attached to them. So yes.


How do you size a junction box for an angle pull an a straight through pull?

the reproduction of plants trachea enzymes bronchi spiracles capillaries in junction box


Can you run a 240v wire from the electrical panel then put a junction box to run it where you want?

A 240 volt wire is the insulation factor of the wire. If you mean a 240 supply source from a distribution panel to a junction box then the answer is yes. You have to keep in mind that the box has to be accessible, meaning that you can get to the box to check the splice within the box. Don't bury the junction box behind the wall board.


Where should the green ground wire attach in a ceiling fan install going direct to a 110 outlet?

The green ground wire should be attached directly to the junction box. That is the metal housing where the house wires enter the outlet.


What type of prewire for a ceiling fan light?

The pre wire for a ceiling fan light should be made with a three wire cable. This cable will have a red, black, and white wire as main conductors. This cable will also have a bare ground wire. This wire should be strung between a two gang switch box to the fixture junction box. This pre wire allows the supply to be either fed to the two gang box. From the two gang switch junction box, one side will be used for the light in the fixture and the other side of the switch junction box, itwill be used for the fan portionin the fixture.