answersLogoWhite

0


Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: What capacity of tonnage of ac needed for 11x12 ft room?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How many square feet in a 11x12 room?

There are 132 square feet in a room that is 11 feet by 12 feet. This can be calculated by multiplying the length (11 feet) by the width (12 feet).


What is the squar foot of 11 by 12 room?

132 square feet 11x12 = 132


How do you determine the capacity tonnage of a split AC required for your bedroom 12ft X 11.8 Ft?

The capacity of a split AC can be determined by a simple formula. The voltage of the AC connector and the size of the room are the two factors that determine the capacity.


How much tonnage is needed to cool a 1600sq feet room?

600 sqft/ton so 2 1/2 ton


If the temperature 1 degree increases then how much Btu capacity needed to cool the room?

hello


How do you convert total heat load into tonnage required for a room?

There are 12000 btu`s in a ton, so divide your total heat gain by 12000 for tonnage.


How much time is needed before you are allowed to enter an engine room after CO2 has been released?

Time for reentry to an engine room after CO2 is released depends on the size of the room, the amount of CO2 released, the amount of ventilation provided to the room, and whether or not the ventilation is working at full capacity.


How many BTU is needed to keep a 300 sq ft room under 90 degrees?

The number of BTUs needed to cool a room depends on factors such as insulation, ceiling height, and climate. On average, a 300 sq ft room would require around 6,000-7,000 BTUs to keep it under 90 degrees Fahrenheit in moderate climates. It's best to consult a HVAC professional to determine the exact BTU capacity needed for your specific room.


Air conditioner tonnage calculation?

Calculating the appropriate tonnage (cooling capacity) for an air conditioner is essential to ensure that the unit effectively cools the desired space. The tonnage required depends on factors such as the room's size, insulation, climate, and heat-generating sources. The British Thermal Units (BTUs) are commonly used to measure cooling capacity. Here's a general guideline for calculating the required tonnage: 1.Determine the Room's Square Footage: Measure the length and width of the room in feet, then multiply these dimensions to get the square footage. For example, a room that is 20 feet long and 15 feet wide has a square footage of 20 x 15 = 300 square feet. 2. Consider the Insulation: If the room is well-insulated, you can use the following BTU formula: BTUs = Square footage x 25 3. Adjust for Insulation and Climate: If the room has poor insulation or is in a particularly hot climate region, you may need to adjust the BTU calculation. Here's a more detailed formula: BTUs = (Square footage x 25) + (Extra BTUs for insulation and climate) The "Extra BTUs for insulation and climate" factor depends on the insulation quality and climate conditions: Well-insulated room: No extra BTUs needed (0) Average insulation: Add 10% to the calculated BTUs Poor insulation: Add 20% to the calculated BTUs Hot climate (sunny and above 90°F): Add 10% to the calculated BTUs Very hot climate (sunny and above 100°F): Add 20% to the calculated BTUs 4. Account for Heat-Generating Sources: If the room has significant heat sources (such as large windows, many occupants, or heat-generating appliances), you may need to add extra BTUs to compensate for this heat load. The exact adjustment depends on the specific heat sources present in the room. 5. Convert BTUs to Tons: Air conditioner capacity is typically measured in tons. To convert BTUs to tons, divide the calculated BTUs by 12,000 (1 ton = 12,000 BTUs). For example, if the calculated BTUs are 24,000, the required tonnage is 24,000 / 12,000 = 2 tons. It's essential to use these calculations as a starting point and consult with a professional HVAC technician to ensure that the air conditioner is correctly sized for your specific needs. Factors such as the number of occupants, local climate, and unique room characteristics can influence the tonnage requirement. Oversized or undersized air conditioners can lead to inefficiency, discomfort, and higher energy bills.


How many btu for cooling a 20x12 room is?

To calculate the BTUs needed to cool a room, multiply the square footage of the room by 20 (which is the recommended cooling capacity in BTUs per square foot). In this case, for a 20x12 room (240 square feet), you would need approximately 4,800 BTUs to effectively cool the space.


How many BTU needed to cool a 190 square foot room?

The estimated cooling capacity needed to cool a 190 square foot room is around 5,000 BTUs per hour. This number may vary depending on factors like insulation, ceiling height, and local climate conditions. It's recommended to consult with a professional to determine the exact BTU requirements for your specific room.


How do you use the word capacity in a sentence?

The capacity of my fuel tank is 15 gallons