answersLogoWhite

0


Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: What does calibration curve mean?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How calibration curve is obtained using flame spectrophotometer?

A calibration curve for a flame spectrophotometer is obtained by measuring the absorbance of a series of standard solutions with known concentrations of the analyte. The instrument records the absorbance values at specific wavelengths. By plotting the absorbance against the concentration of the standard solutions, a linear calibration curve is achieved. This curve can then be used to determine the concentration of an unknown sample based on its absorbance value.


What is the calibration curve of orifice meter?

The calibration curve for an orifice meter will depend on the size of the orifice, the size of the pipe and the pressure loss over the meter. Typical calibration curves have pressure (or head) loss on the vertical (y) axis and flow rate on the horizontal (x) axis.


What is the calibration curve for rotameter?

A calibration curve for a rotameter is a graphical representation showing the relationship between the flow rate of a fluid passing through the rotameter and the corresponding reading on the rotameter display. This curve is generated by calibrating the rotameter with known flow rates and correlating them with the rotameter readings. It helps in accurately determining the flow rate of a fluid based on the rotameter reading.


Why calibration curve method is more reliable as compared to a single point method?

Why Calibration curve method is more reliable than single point method?Read more: Why_Calibration_curve_method_is_more_reliable_than_single_point_method


How do you calculate the limit of detection from a calibration curve?

The limit of detection (LOD) can be calculated as 3 times the standard deviation of the y-intercept divided by the slope of the calibration curve. This value represents the smallest concentration of analyte that can be reliably measured with the method.


How do you calibrate a gas chromatography instrument?

To calibrate a gas chromatography instrument, use a mixture of known compounds to create calibration standards. Inject these standards into the GC instrument at different concentrations to create a calibration curve. The instrument software will then use the calibration curve to quantify and identify compounds in unknown samples based on their retention times.


What are the ideal characteristics of a calibration curve?

The ideal characteristics of a calibration curve include a linear relationship between analyte concentration and response, a high correlation coefficient (R-squared value) close to 1, a wide dynamic range, and low limits of detection and quantification. Additionally, the curve should be reproducible and stable over time.


How can you calculate the activity of alfa amylase based on absorbance values by DNS method?

You need a calibration curve for D-glucose


What does chromatography help find?

Chromatography can help separate individual components of a complex mixtures AND quantify them with the use of a calibration curve.


Would the construction of a calibration curve based on peak high give accurate results for the determination of caffeine in this experiment?

No, a calibration curve based on peak height alone may not give accurate results for the determination of caffeine. Peak area is a more reliable measure for quantification as it takes into account both peak height and width, which can be influenced by various factors in the experiment such as sample matrix effects and instrument settings. Using peak area for the calibration curve would improve the accuracy and reliability of the results.


Would it be reliable to use the simple calibration curve method for the determination of potassium by flame photometry in seawater?

The simple calibration curve method can be reliable for determining potassium in seawater by flame photometry if proper calibration standards are prepared in a similar matrix as the samples to account for any matrix effects. Additionally, ensuring that the instrument is properly calibrated and maintained is crucial for accurate results. Controls and replicates should also be included to ensure the method's reliability and precision.


What does curve mean?

curve means Bend