Ground and neutral should only be connected at the main electric panel to prevent parallel neutral currents. If it is a new installation, you must provide four wires (two hots, 1 neutral, & 1 ground) and connect to the four separate (appropriate) places on the dryer. If it is an existing installation and it only has three wires (two hots and a neutral) connect the neutral to both the neutral and ground connection of the dryer (the National Electrical Code allows this exception for older homes). Call a qualified electrician to do any electrical work.

User Avatar

Wiki User

15y ago

Still curious? Ask our experts.

Chat with our AI personalities

JudyJudy
Simplicity is my specialty.
Chat with Judy
RafaRafa
There's no fun in playing it safe. Why not try something a little unhinged?
Chat with Rafa
DevinDevin
I've poured enough drinks to know that people don't always want advice—they just want to talk.
Chat with Devin
More answers

No, ground wires and neutral wires should not be connected together at the dryer. The ground wire provides a safe path for electricity to be directed away in the event of a fault, while the neutral wire carries the return current to the power source. It is important to keep them separate to ensure proper grounding and prevent electrical hazards.

User Avatar

AnswerBot

10mo ago
User Avatar

Add your answer:

Earn +20 pts
Q: Can groundwire be together with neutral wire at the dyer?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Why are the live wire and neutral wire never joined together?

The live wire carries current from the electrical source to the device, while the neutral wire completes the circuit by returning the current back to the source. If the live and neutral wires were joined together, it would create a short circuit, potentially leading to overheating, electrical fires, or damage to the electrical system.


How do you wire a 220 3 wire breaker to 4 wire dyer?

Buy a 3 wire cord for your dryer.


When connecting chain switch what is done with the neutral wire and white wire from ballast?

The neutral wire from the chain switch is connected to the white wire from the ballast. They should be connected together using a wire nut to ensure proper circuit completion and safe operation of the light fixture.


Can you connect the ground and neutral coming out of a cooktop to the ground of a nm8 2 wire?

No, the ground and neutral wires should not be connected together at the cooktop. The ground wire from the cooktop should be connected to the ground wire in the NM-B cable, and the neutral wire from the cooktop should be connected to the neutral wire in the NM-B cable. It is important to follow proper wiring practices to ensure safety and compliance with electrical codes.


How should old 3 wire stove be wired in panel bare wire to neutral or ground or both?

The bare wire from the old 3-wire stove should be connected to the grounding terminal in the panel. The neutral and ground should not be bonded together at the stove. If the stove requires a 4-wire connection, it's best to run a new 4-wire circuit to meet current electrical codes for safety.