answersLogoWhite

0

yes

Another (corrected) answer.NO! The circuit breaker is there to protect the wiring from overheating. It wouldn't matter where on the circuit you decided to put the 14 gauge wire, you would need to change the breaker to 15 Amp if you did that. Using 14 gauge wire on a 20 amp circuit is a fire hazard and contrary to UBC.

Contact your local building and zoning department to verify.

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Natural Sciences

Can you use 10 gauge wire to connect a 2 15 amp outlets to a 30 amp breaker?

No, it is not safe to use 10 gauge wire with a 30 amp breaker as the wire is not rated for that high of a current. It is important to use the correct wire gauge that matches the breaker amperage to prevent overheating and potential fire hazards. For a 30 amp breaker, you should use at least 10 gauge wire.


Can 13 gauge wire be connected to a 20 amp breaker?

No, because NEC says that 12 AWG wire is the smallest wire that can safely handle 20 A. If you installed a smaller wire on a 20 A breaker you could possibly overheat the wire and cause it to fail, which can start a fire. It would not be to code. And the National Electrical code does not list a 13 gauge wire.


Can you connect a 14 gauge extension cord to a 12 gauge extension cord?

Yes, as long as the fuse or circuit breaker is rated for the smallest wire in the circuit, which in this case appears to be the 14 guage. Suppose the 14 guage is rated for 15 amps and the the 12 guage is rated for 20, and there is a 20-amp breaker on the circuit. Now suppose you have a short that draws 18 amps. The 14 guage wire will burn and catch fire, yet the breaker will not trip. That could be dangerous.


If a 1950 era house has 10 gauge wiring for lights and outlets can you safely extend wiring with 12-2 for additional lights and outlets?

Mixing different gauge wires in the same circuit is not recommended as it can lead to electrical hazards. It is better to use the same gauge wire throughout the circuit to maintain consistency in the electrical load. If you're adding new lights and outlets, it's best to use the same gauge wire as the existing one.


14 gauge wire can be on what size circuit breaker?

A 14 gauge wire is typically used on a 15 amp circuit breaker. It is not recommended to use a larger circuit breaker with a smaller wire size as this can create a fire hazard.

Related Questions

Can you use 10 gauge wire to connect a 2 15 amp outlets to a 30 amp breaker?

No, it is not safe to use 10 gauge wire with a 30 amp breaker as the wire is not rated for that high of a current. It is important to use the correct wire gauge that matches the breaker amperage to prevent overheating and potential fire hazards. For a 30 amp breaker, you should use at least 10 gauge wire.


Can 13 gauge wire be connected to a 20 amp breaker?

No, because NEC says that 12 AWG wire is the smallest wire that can safely handle 20 A. If you installed a smaller wire on a 20 A breaker you could possibly overheat the wire and cause it to fail, which can start a fire. It would not be to code. And the National Electrical code does not list a 13 gauge wire.


What gauge wire should be used for a 30 amp breaker?

For a 30 amp breaker, a 10-gauge wire should be used.


What gauge wire should be used for a 60 amp breaker?

For a 60 amp breaker, a 6-gauge wire should be used.


How do you wire a baseboard heater?

To wire a baseboard heater, you need to connect it to a dedicated circuit breaker in your electrical panel using the appropriate gauge wire. Make sure to follow the manufacturer's instructions and local electrical codes for proper installation. It is recommended to hire a licensed electrician for this task to ensure safety and compliance.


How can I safely connect a wire generator to a breaker box?

To safely connect a wire generator to a breaker box, follow these steps: Turn off the main power supply to the breaker box. Install a transfer switch to isolate the generator from the utility power. Connect the generator to the transfer switch using the appropriate wiring. Connect the transfer switch to the breaker box using the correct gauge wire. Test the connection to ensure it is working properly before restoring power. It is recommended to consult a licensed electrician for assistance to ensure the connection is done safely and correctly.


Can 20 amp breaker with 12 gauge wire handle 8 recessed lights?

Yes. I am assuming this is a residential question. A better answer is...if the 8 recessed lights draw fewer than 16 amps together, it is good.


Can you connect a 14 gauge extension cord to a 12 gauge extension cord?

Yes, as long as the fuse or circuit breaker is rated for the smallest wire in the circuit, which in this case appears to be the 14 guage. Suppose the 14 guage is rated for 15 amps and the the 12 guage is rated for 20, and there is a 20-amp breaker on the circuit. Now suppose you have a short that draws 18 amps. The 14 guage wire will burn and catch fire, yet the breaker will not trip. That could be dangerous.


What are the electrical requirements for a 30 amp electric range?

A 30 amp electric range typically requires a dedicated 240-volt circuit with a 30 amp breaker and 10-gauge wiring.


How do you wire an electric baseboard heater?

To wire an electric baseboard heater, you need to connect it to a dedicated circuit breaker in your electrical panel using the appropriate gauge wire. Make sure to follow the manufacturer's instructions and local electrical codes for proper installation. It is recommended to hire a licensed electrician for this task to ensure safety and compliance.


How should I properly wire a 30 amp breaker for my electrical circuit?

To properly wire a 30 amp breaker for your electrical circuit, you should use the appropriate gauge wire (typically 10 gauge for a 30 amp circuit), connect the wire to the breaker terminal, and then run the wire to the outlet or device you are powering. Make sure to follow all local electrical codes and safety guidelines when performing this task.


What is the wire size required for 1800 watts for lamps?

14 gauge will handle it with a 15 amp breaker. If you use 12 gauge use a 20 amp breaker.