answersLogoWhite

0


Best Answer

15 amps

User Avatar

Wiki User

14y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

6mo ago

A 14 gauge wire is typically used on a 15 amp circuit breaker. It is not recommended to use a larger circuit breaker with a smaller wire size as this can create a fire hazard.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: 14 gauge wire can be on what size circuit breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

When installing a circuit breaker do you size the breaker to correct wire size or the device its controlling?

When installing a circuit breaker, you size the breaker based on the wire size. The breaker should be matched to the ampacity of the wire to ensure proper protection against overloads and short circuits. The device being controlled by the breaker is not a determining factor in sizing the breaker.


Ground wire size for 200?

The size of the ground wire for a circuit is typically based on the size of the circuit breaker protecting that circuit. For a 200 amp circuit breaker, the recommended ground wire size is 4/0 AWG (American Wire Gauge) copper wire. This wire size helps ensure that the ground wire can safely carry any fault currents that may occur in the electrical system.


Can you connect 14 gauge wire to 12 gauge wire on a 20 amp breaker if the 14 gauge is the end of the run and dedicated to lights?

It is not recommended to connect a 14 gauge wire to a 12 gauge wire on a 20 amp breaker, as this can create a safety hazard. It's important to match the wire gauge to the circuit breaker rating to prevent overheating and potential fire hazards. It would be best to run a continuous 12 gauge wire for this circuit.


What wire size is required for a branch circuit with 10 outlets and a 15 amp breaker?

With a 15 A breaker you need 14 Gauge wire. Normally you would only put 8 outlets on a 15 A circuit. If you have the option you shoudl consider a 20 A circuit, use 20A receptacles and 12 gauge wire. Comment: The question was on a homeowners electrical exam. My answer was also 14 gauge however, the tester said the answer was 12 ga. I thought maybe there was something special about the 10 outlets. For example, 10x180 VA per outlet/120V = 15 A which is right at the limit for 14 ga but would be 75% for the 12 ga wire.


What is the smallest copper wire size permitted by the national electric code for a 20 amp single phase electrical circuit?

I think you mean either what is the correct size or minimum wire size needed when a branch circuit is protected by a 20 A breaker. The size is 12 American Wire gauge (AWG). 14 AWG is used for 15 A circuit and 10 AWG for a 30 A breaker. The lower the gauge the larger the cross-section of the wire.

Related questions

What size circuit breaker for GFCI circuit in a normal size bath?

Normally it is a 20 amp using AWG 12/2 gauge wire. But it really depends on what size wire is on that circuit. If it is white AWG 14 gauge then use a 15 amp breaker. If it is yellow AWG 12 gauge then use a 20 amp breaker.


When installing a circuit breaker do you size the breaker to correct wire size or the device its controlling?

When installing a circuit breaker, you size the breaker based on the wire size. The breaker should be matched to the ampacity of the wire to ensure proper protection against overloads and short circuits. The device being controlled by the breaker is not a determining factor in sizing the breaker.


Ground wire size for 200?

The size of the ground wire for a circuit is typically based on the size of the circuit breaker protecting that circuit. For a 200 amp circuit breaker, the recommended ground wire size is 4/0 AWG (American Wire Gauge) copper wire. This wire size helps ensure that the ground wire can safely carry any fault currents that may occur in the electrical system.


Can you connect 14 gauge wire to 12 gauge wire on a 20 amp breaker if the 14 gauge is the end of the run and dedicated to lights?

It is not recommended to connect a 14 gauge wire to a 12 gauge wire on a 20 amp breaker, as this can create a safety hazard. It's important to match the wire gauge to the circuit breaker rating to prevent overheating and potential fire hazards. It would be best to run a continuous 12 gauge wire for this circuit.


What gauge wire should be used with a 60amp circuit breaker?

Use AWG # 6 wire.


Can you wire 10 Gauge and 12 Gauge in the same circuit?

Yes but there are two stipulations, one that the join or splice must be made in a junction box that is accessible and has a removable cover and the second stipulation is that the breaker that is supplying the power can not be larger that the smallest conductor. In this case no breaker larger that a 20 amp breaker as #12 wire is only rated at 20 amps..


What is the margin of safety with selecting circuit breakers?

The NEC requires that if the intended rating of a circuit corresponds to a standard size breaker then that size breaker must be used. In most instances, "rating of a circuit" means the intended connected load plus 25%. If the intended rating of a circuit does not correspond to a standard size breaker, you can go up to the next standard size without any other adjustments. In most circumstances, besides what I've already stated, a 14 gauge copper wire cannot be connected to a breaker larger than 15 amps, 12 gauge copper to a 20 amp breaker, and 10 gauge copper to a 30 amp breaker.


What wire size is required for a branch circuit with 10 outlets and a 15 amp breaker?

With a 15 A breaker you need 14 Gauge wire. Normally you would only put 8 outlets on a 15 A circuit. If you have the option you shoudl consider a 20 A circuit, use 20A receptacles and 12 gauge wire. Comment: The question was on a homeowners electrical exam. My answer was also 14 gauge however, the tester said the answer was 12 ga. I thought maybe there was something special about the 10 outlets. For example, 10x180 VA per outlet/120V = 15 A which is right at the limit for 14 ga but would be 75% for the 12 ga wire.


Is it safe to use 10 gauge wire on a 20 amp breaker for a microwave?

No, 10 gauge wire requires the use of a 30 amp breaker. A 20 amp breaker is only used on 12 gauge wire.


What size amp circuit breaker should be used for 110 outlet?

The size breaker you use is determined by the size wire used in the circuit. If you use AWG #12/2 wire then use a 20 amp breaker. If you use AWG # 14/2 then use a 15 amp breaker.


How do you change wire fuse for circuit breaker?

A circuit breaker does not have a wire fuse in it.


What is the smallest copper wire size permitted by the national electric code for a 20 amp single phase electrical circuit?

I think you mean either what is the correct size or minimum wire size needed when a branch circuit is protected by a 20 A breaker. The size is 12 American Wire gauge (AWG). 14 AWG is used for 15 A circuit and 10 AWG for a 30 A breaker. The lower the gauge the larger the cross-section of the wire.