Of course it is physically possible. However, I strongly suggest you check with a qualified electrician who knows the particular electrical and building codes for your area as they can vary. Done incorrectly, you run the possibility of electrocuting yourself or someone else who uses that outlet, or setting your house on fire.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

1mo ago

No, a standard 20A outlet is rated for 120V. Wiring 208V to a standard 20A outlet would pose a safety hazard and could damage your electrical devices. If you need a higher voltage, consult an electrician to install the appropriate outlet.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can you wire 208v to a standard 20a outlet?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Can you properly change a 3-prong 240V outlet looks like standard plug but horizontal to the NEMA twistlock 20A style if they use a different number of wires extra ground neutral on a twistlock type?

Yes, you can convert a 3-prong 240V outlet to a NEMA twist lock 20A style outlet, although you may need to rewire the circuit. The twist lock outlet typically requires an extra ground wire in addition to the hot and neutral wires. It is important to follow electrical codes and guidelines when making any changes to electrical outlets for safety reasons.


How do you wire a 6-20R outlet?

To wire a 6-20R outlet, connect the black (hot) wire to the brass screw terminal, the white (neutral) wire to the silver screw terminal, and the green (ground) wire to the green screw terminal. Make sure to secure the wires using the appropriate wire connectors and tighten the terminal screws. Always ensure the power is turned off before working on electrical outlets.


Can you put an extension cord on a treadmill 20 amp?

No, it is not recommended to use an extension cord with a treadmill that requires a 20-amp outlet. Extension cords can overheat and pose a fire hazard when used with high-amperage appliances like treadmills. It's best to have a dedicated outlet installed by a qualified electrician to safely power your treadmill.


Can a regular 120 volt outlet be converted to a 120 v 20 amp single phase simply by changing the breaker and rewiring the outlet want to use a mig welder occasionally?

No, converting a regular 120V outlet to a 120V 20 amp outlet requires more than just changing the breaker and rewiring the outlet. You would also need to ensure that the wiring in the walls can handle the higher amperage and that the outlet itself is rated for 20 amps. It's best to consult with a licensed electrician to ensure the safety and proper installation of the upgraded outlet for your welding needs.


What does a GFCI outlet look like?

A GFCI outlet typically has two buttons in the center - one labeled "Test" and the other "Reset." It also has slightly larger dimensions than a standard outlet and may have "TEST" and "RESET" written on the front.

Related questions

What is voltage for sun quest pro 24s tanning bed?

120V, but 20A, so not a regular outlet or wire.


Can you properly change a 3-prong 240V outlet looks like standard plug but horizontal to the NEMA twistlock 20A style if they use a different number of wires extra ground neutral on a twistlock type?

Yes, you can convert a 3-prong 240V outlet to a NEMA twist lock 20A style outlet, although you may need to rewire the circuit. The twist lock outlet typically requires an extra ground wire in addition to the hot and neutral wires. It is important to follow electrical codes and guidelines when making any changes to electrical outlets for safety reasons.


A 208V water heater can te be replaced by a 240V water heater?

Yes but you will not get the full watt rating out of the tank. Watts = amps x volts. Say the tank draws 20 amps. 20A x 240V = 4800 watts. 20A x 208V = 4160 watts. It will take longer to heat your water with less wattage.


Can a 30A 240V outlet be replaced by a 20A 240V one?

You can, but be advised that whatever you plug into the new outlet should not exceed 5000W capacity (20A x 250V = 5000W)or you could risk overheating the new outlet with serious results. To prevent this, you should make sure the circuit breaker is a 20A also.


How do you wire a 6-20R outlet?

To wire a 6-20R outlet, connect the black (hot) wire to the brass screw terminal, the white (neutral) wire to the silver screw terminal, and the green (ground) wire to the green screw terminal. Make sure to secure the wires using the appropriate wire connectors and tighten the terminal screws. Always ensure the power is turned off before working on electrical outlets.


What gauge wire for 20A?

12 AWG.


How do you upgrade from 120V 15A to 120V 20A or from 240V 20A to 240V 30A?

You have to replace the wire (as you are increasing the current capacity), the outlet, and the breaker. Essentially you have to remove the old circuit and put in a new one. You can't reuse parts of the old circuit as you are increasing the current capacity and they would be underrated.


Is 1500 watts too much to run on same outlet with computer?

if the outlet is 20A it's ok on a 15A outlet depends what you what to run it may be too much.


Can an outlet that provides 120V 20A to a device also provide correct requirements for a device that requires 110-140V 60hz 20A?

There is no problem at all. It is the breaker that protects the wire and limits the current to 20 amps. Voltages in most supply systems vary depending on the time of day and where you are situated on the line in the system.


What are the names of the three slots in an electric outlet?

hot - this is the short slot - connected to the black wireneutral - this is the long slot (15A) or T shaped slot (20A) - connected to the white wiresafety ground - this is the round or U shaped slot - connected to the green wire (sometimes this is a bare wire)


What are the names of the three slots in an electrical outlet?

hot - this is the short slot - connected to the black wireneutral - this is the long slot (15A) or T shaped slot (20A) - connected to the white wiresafety ground - this is the round or U shaped slot - connected to the green wire (sometimes this is a bare wire)


Can you put an extension cord on a treadmill 20 amp?

No, it is not recommended to use an extension cord with a treadmill that requires a 20-amp outlet. Extension cords can overheat and pose a fire hazard when used with high-amperage appliances like treadmills. It's best to have a dedicated outlet installed by a qualified electrician to safely power your treadmill.