Use the National Electric Code wire size tables for various applications.

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Natural Sciences

How many amps will 16 gauge stranded auto wire handle?

According to NEC, it's max rating in free air is 18 amps.


How many amps will 10 wire hold?

A 10-gauge wire can typically handle around 30-35 amps of current. It is important to consult the National Electric Code and wire manufacturer specifications to determine the maximum current carrying capacity of a specific wire in a given installation.


How do you calculate a sises of cable used for an appliance?

Wire sizes and ampacity are regulated by code. # 14 wire 15 amps, #12 wire 20 amps, #10 wire 30 amps, #8 wire 40 amps, #6 wire 60 amps. These are the most common, a slight variation in amperage depending on the insulation factor.


Can you use awg12 wire for your 220 stove?

No. I wouldn't try it. Check on the number of amps that the stove uses. Then you can calculate what size wire you will need. The amp rating on a #12 wire is 20 amps. A 240 volt stove needs a minimum of 40 amps. This supply is brought to the stove on a #8 wire rated at 45 amps R90 insulation. This supply wire is protected by a two pole 40 circuit breaker situated in your electrical panel. If you use a #12 wire and apply the total stove load, the insulation will melt off the wire and short out.


What is the max amps for 0 gauge wire?

The maximum amperage of a 0 gauge wire typically ranges from 150 to 200 amps for automotive applications. However, it is important to consult the specific manufacturer's guidelines and consider factors such as temperature and installation conditions to ensure the safe use of the wire.

Related Questions

What is the max amps for 14 gauge wire at 12 volts?

15 amps


What is the max amps for a 4 gauge wire can 4 gauge feed a 100A breaker box?

Yes, # 4 AWG copper and 100 amps is the max.


How can you calculate the current carrying capacity of 1 sq mm wire?

4amps can pass in 1sqmm of wire max it is universal. In the UK 1 sq. mm wire can take 10 amps max according to tables. Cables that become warm in use should be replaced by a thicker gauge.


How many amps will 16 gauge stranded auto wire handle?

According to NEC, it's max rating in free air is 18 amps.


How can i calculate amperes for transformers?

Find the wire from the secondary of the transformer. If it's a step-down transformer the thicker wire is the secondary. Measure its diameter in inches and calculate its cross-section area in square inches. The current rating for transformer wire is 1000 amps per square inch, or 1.55 amps per square mm.


How many amps will 10 wire hold?

A 10-gauge wire can typically handle around 30-35 amps of current. It is important to consult the National Electric Code and wire manufacturer specifications to determine the maximum current carrying capacity of a specific wire in a given installation.


How many amps will taken in sq mm copper wire?

10 amps


What is the maximum current rating for a wire that can safely handle 10 wire amps?

The maximum current rating for a wire that can safely handle 10 wire amps is 10 amps.


How do you calculate a sises of cable used for an appliance?

Wire sizes and ampacity are regulated by code. # 14 wire 15 amps, #12 wire 20 amps, #10 wire 30 amps, #8 wire 40 amps, #6 wire 60 amps. These are the most common, a slight variation in amperage depending on the insulation factor.


How many amps will 4 gauge wire handle?

The amps that a four gauge wire will handle will depend with the thickness of the wire. If the wire is thin, the four gauge will handle 95 amps.


What is the Max amps for 6 gauge?

50 amps


Can you use awg12 wire for your 220 stove?

No. I wouldn't try it. Check on the number of amps that the stove uses. Then you can calculate what size wire you will need. The amp rating on a #12 wire is 20 amps. A 240 volt stove needs a minimum of 40 amps. This supply is brought to the stove on a #8 wire rated at 45 amps R90 insulation. This supply wire is protected by a two pole 40 circuit breaker situated in your electrical panel. If you use a #12 wire and apply the total stove load, the insulation will melt off the wire and short out.