Yes, if you are running it no farther than 100 feet. If you are going over 100 feet use AWG # 10 wire on the 20 amp breaker.
Wiki User
∙ 10y agoNo, a 12 gauge wire is rated for 20 amps, which matches the breaker size. It is not recommended to use a wire that matches the breaker size as it can result in overheating and potentially cause a fire hazard. Consider using a thicker wire, such as 10 gauge, for the 20 amp breaker to ensure safety for the sub panel.
For a 100' run from the panel to the RV using a 30amp breaker, you should use 10 gauge wire to ensure safe and efficient power delivery. This wire gauge is appropriate for the distance and the current capacity of the breaker.
No, it is not safe to use 10 gauge wire with a 30 amp breaker as the wire is not rated for that high of a current. It is important to use the correct wire gauge that matches the breaker amperage to prevent overheating and potential fire hazards. For a 30 amp breaker, you should use at least 10 gauge wire.
Look to see if the 30 amp panel is fed with a two wire or a three wire. If it is a two wire then you are out of luck. If the panel is fed with a three wire then the panel should have the neutral terminated in the panel. It is this neutral that you need for 120 volt connections. You didn't state how many panel slots there are in the panel. If you are able install a 15 amp breaker into the panel and connect the wires going to the load. The black wire will go to the breaker and the white wire will go to the neutral bar in the panel.
No, it is not recommended to connect 13 gauge wire to a 20 amp breaker. The wire gauge should match the amp rating of the breaker to prevent overheating and potential fire hazards. In this case, a 20 amp breaker should be used with at least 12 gauge wire.
A 14 gauge wire is typically used on a 15 amp circuit breaker. It is not recommended to use a larger circuit breaker with a smaller wire size as this can create a fire hazard.
For a 100' run from the panel to the RV using a 30amp breaker, you should use 10 gauge wire to ensure safe and efficient power delivery. This wire gauge is appropriate for the distance and the current capacity of the breaker.
No, it is not safe to use 10 gauge wire with a 30 amp breaker as the wire is not rated for that high of a current. It is important to use the correct wire gauge that matches the breaker amperage to prevent overheating and potential fire hazards. For a 30 amp breaker, you should use at least 10 gauge wire.
No, 10 gauge wire requires the use of a 30 amp breaker. A 20 amp breaker is only used on 12 gauge wire.
Look to see if the 30 amp panel is fed with a two wire or a three wire. If it is a two wire then you are out of luck. If the panel is fed with a three wire then the panel should have the neutral terminated in the panel. It is this neutral that you need for 120 volt connections. You didn't state how many panel slots there are in the panel. If you are able install a 15 amp breaker into the panel and connect the wires going to the load. The black wire will go to the breaker and the white wire will go to the neutral bar in the panel.
no
No. A 20 amp breaker needs 12 gauge wire.
No, it is not recommended to connect 13 gauge wire to a 20 amp breaker. The wire gauge should match the amp rating of the breaker to prevent overheating and potential fire hazards. In this case, a 20 amp breaker should be used with at least 12 gauge wire.
The question isn't what you're powering with a particular gauge of wire, but what's the current draw. If the metal halide light can run on a 15 Amp breaker (from the breaker panel), fine use your metal halide in your residential application and run it on the 14 gauge wire.
A 14 gauge wire is typically used on a 15 amp circuit breaker. It is not recommended to use a larger circuit breaker with a smaller wire size as this can create a fire hazard.
It is not recommended to connect a 14 gauge wire to a 12 gauge wire on a 20 amp breaker, as this can create a safety hazard. It's important to match the wire gauge to the circuit breaker rating to prevent overheating and potential fire hazards. It would be best to run a continuous 12 gauge wire for this circuit.
You can use a 20-amp single pole breaker for 12-2 wire. This is the standard size breaker for 12-gauge wire in residential applications.
Copper SE cable gauge 00 from the meter socket to the breaker panel for a 200A service. Then 8, 10, 12, and 14 gauge wire depending on the load.