In Canada the requirement for grounding purposes calls for two 5/8" x 10' ground rods placed 10' apart. If rocky ground is encountered, then a grounding plate can be installed. The grounding plate dimensions are 10" wide x 16" long x 1/4" thick. They are galvanized coated and must be buried 24 inched below grade.

User Avatar

Wiki User

11y ago

What else can I help you with?

Continue Learning about Natural Sciences

Downstream of the electrical service box the neatral and gound wire should be separted?

Yes, it is important to keep the neutral and ground wires separated downstream of the electrical service box. Mixing these two wires can create potential safety hazards, such as electrical shocks or fires. It is crucial to follow proper wiring practices and guidelines to ensure a safe electrical installation.


Can the bare grounded neutral conductor of a service be buried directly in the ground?

A bare grounded neutral should never get close to the ground if it is wired properly. When the neutral leaves the meter base it is in conduit and should enter into the distribution panel where it connects to the neutral buss. It is at this junction that the copper ground wire is connected after coming from the outside ground rod or ground plate which ever grounding system was used.


What is the minimum size of service entrance conductor?

The wire that is used for connecting the ground rod or plate to the electrical distribution is governed by the size of the electriclal distribution. In Canada a #6 bare copper is the minimum size for a 200 amp service.


Where is a ground rod for a house is driven?

Look for it in the vicinity below the electrical house meter. There should be a bare wire coming out of the house in that area and if followed should take you right to the ground rod. There might be one 10' rod or two 6' rods. The wire will probably be buried just under the surface of the ground.


If you have a 240V hookup with a red black and white wire can you drive a copper rod into the ground and hook up the green wire to that?

You could, but if you're going to do that then why not ground the entire service entrance panel? ...and you need to drive (if I remember correctly)...about 7 feet into the ground to be effective.

Related Questions

What color is a ground wire in an electrical distribution?

The main electrical ground wire is sized to the service and is non insulted bare copper. Branch circuit grounds are green in conduit installations and bare copper again in house wiring cables.


What is rod earthing?

It is the installation of ground rods at a service entrance distribution to bring the relative resistance to ground to be within 5 ohms of the utility's distribution network. This grounding system is then connected to the service distribution with a calculated size wire and connected to the distribution at a point within the distribution panel, where the service neutral wire joins the neutral bus bar.


Before installing the metal distribution boxes an electrical technician will need to remove the electrical bonding of the neutral and ground?

Conductor


What could the problem be if there is power at the breaker box ground wire to the water pipe?

The problem sounds like the water pipe is not bonded to the ground wire of the distribution. These two wires should have a potential of zero between them once they are bonded together as per electrical code recommendations.This must be an older installation as nowadays most new water pipe installations use PVC to service a water supply to the home. In this case the PVC water supply pipe does not need to be bonded to the ground wire of the distribution service.


Downstream of the electrical service box the neatral and gound wire should be separted?

Yes, it is important to keep the neutral and ground wires separated downstream of the electrical service box. Mixing these two wires can create potential safety hazards, such as electrical shocks or fires. It is crucial to follow proper wiring practices and guidelines to ensure a safe electrical installation.


What is an electrode conductor?

It is the conductor that is used in service distribution panels that bonds the distribution panel's neutral bus bar to the ground electrode (rod). This brings all of the distribution panel neutrals that are connected to the same supply system to the same potential, that being zero. Should a supply service neutral open this ground wire will maintain the systems integrity until repairs can be made.


A jumper wire should be used to bridge the electrical ground across?

A jumper wire should use to bridge electrical ground across?


Can you crimp copper grounding electrode to aluminum neutral of service entrance?

You should not have to crimp the copper grounding electrical wire to the aluminium service neutral. There is only one place where these two wires should meet. In the service distribution panel there is a neutral block where the two wires are connected. There are individual terminal points in the block. Tighten the ground rod wire under one of these points and place the incoming service neutral under another point in the same block. In this same block there will be a machine screw that bonds the neutral block to the distribution panel's enclosure.


What is an grounding electrode conductor?

It is the conductor that is used in service distribution panels that bonds the distribution panel's neutral bus bar to the ground electrode (rod). This brings all of the distribution panel neutrals that are connected to the same supply system to the same potential, that being zero. Should a supply service neutral open this ground wire will maintain the systems integrity until repairs can be made.


If the distribution cable to the primary distribution center is entrenched where should it protude from the ground?

no closer than 6 feet


What mean Frame Ground?

The frame of a device is usually the supporting structure that holds the electrical device. The electrical code requires that the frame of any electrical device be brought down to ground potential. This is done with a ground wire taken from the frame of the device and connected to the service distribution ground. This is also classed as a bond wire. Now if a fault current occurs any where in the bonded system, the fault current will travel back to the distribution panel and trip the circuit breaker of the faulted circuit removing the voltage from the faulted circuit..


Where should the ground wire be connected in the electrical circuit?

The ground wire should be connected to the grounding terminal or bus bar in the electrical circuit to provide a path for excess electrical current to safely flow to the earth.