A four wire receptacle would normally be used in a poly phase circuit. For example, a 240 VAC branch will have two "hot" wires (conductors), one neutral (grounded) conductor, and a grounding conductor.

Older circuits for dryers and ovens, for example, used only three wires. New NEC standards allow for the use of a four conductor arrangement so all conductors are delivered to the receptacles on the branch.

When replacing the three wire receptacle with a four wire receptacle, you should run a new branch which includes all of the necessary conductors to make the connection correctly.

Otherwise, connect only the three that you need. This is unsafe, though, since any subsequent homeowner may assume that the receptacle is fully wired (as they should). This would also be illegal in the eyes of the NEC.

<<>>

A four blade dryer plug is the new code and should not be changed to a three blade cord. What should be done is to change the three blade receptacle to a four blade receptacle. The only difference in the receptacle wiring is that the position of the neutral wire and the addition of a ground wire being brought out to the dryer on a separate blade to match the ground wire on the plug. Shut the circuit to the dryer to the off position. Opening up the receptacle you will find now two hot wires to the outside blades and a neutral to the center pin. Look in the back of the box and you will see a ground wire wrapped around a screw that grounds the dryer feed wire. From this ground wire add an extension of six inches. This new wire then connects to the fourth terminal on the new four blade receptacle. Looking at the new receptacle you should have the two hot wires on the outside terminals X and Y, white (neutral) to the L shaped W blade and the newly installed ground wire to the U shaped ground G blade. This receptacle is a NEMA 14-30R, 3 pole 4 wire grounding receptacle.

User Avatar

Wiki User

11y ago

What else can I help you with?

Continue Learning about Natural Sciences

Will GFCI work properly if 240 volt split into one 3 wire 120 volt circuit?

No, a GFCI outlet is designed for use with standard 120-volt circuits. Attempting to use a GFCI outlet with a 240-volt split circuit could cause damage to the outlet, the circuit, and could present a safety hazard. It is not recommended to use a GFCI outlet in this manner.


What is a four prong outlet used for?

There are a couple of catagories for plug descriptions. Straight blade and twist lock blade. The amperage and voltage rating is embossed on the plug (trade name for plug is cap, wall part receptacle). See related links for a chart.


In hooking up a 240V Air Conditioner you have four wires but only three on outlet What three go on receptacle Red Black White Copper?

For a 240V with ground outlet you will connect black (hot) to one brass screw, red (hot) to the other brass screw, and bare (ground) to the green screw. Cap white (neutral) with a wire nut. It is for 240/120V appliances. If you don't fully understand this buy a book. This is a very basic question. If you don't understand which wire is which you could make a serious mistake causing fire or death.


How many total hot termanals are there on a normal outlet plug?

Answer for USA, Canada and countries running a 60 Hertz supply service.Need to know the voltage of the outlet plug. On a 120 volts outlet there is one hot terminal and on a 240 volt outlet there are two hot terminals.


How do you get 240 volts out of a 110 outlet?

You would have to run new wires to obtain 240 volts or use a step-up transformer.

Related Questions

How do you connect a 3 wire 120 outlet to a 4 wire 240 outlet?

You don't.


How do you run 4 prong 240 volt outlet?

you must run the proper size wire based on the ampacity needed, wire must have four conductors including the gound


What are the specifications and compatibility of the NEMA 14-60 electrical outlet?

The NEMA 14-60 electrical outlet is a type of outlet that is commonly used for high-powered appliances like electric stoves and dryers. It has a voltage rating of 240 volts and a current rating of 60 amps. The outlet has four prongs, with two hot wires, a neutral wire, and a ground wire. It is compatible with appliances that require a 240-volt power supply and can handle up to 60 amps of current.


How can I wire a 240 V single-phase outlet from a commercal building with 3-phase service 4- wire?

A three phase four wire commercial distribution service will not give you 240 volts. The nearest voltage you can get is 208 volts. It is a wye connection which gives you 208 volts between the three legs and 120 volt between any of the three legs and ground. This ground point is the systems neutral point.


What size wire do you need for a 200 Amp 240 Volt 3 phase 4 wire service on a doctors office?

You might be out of luck. Three phase delta 240 volt services are a thing of the past. As far as I know there never was a 240 volt three phase four wire. The line to neutral voltage would be 240/1.73 = 139 volts which is of no use to anyone. Three phase four wire system for business and commercial use these days is 120/208 volts. A 3/0 copper conductor with an insulation factor of 90 degrees C is rated at 225 amps.


Can you wire usa 4 wire 240 volt to UK 3 wire 240volt American boat in UK waters?

A four wire plug suggests to me that it is for split voltages. 120/240, hot - neutral - hot - ground will be the four blade connections for shore power in the US. With UK shore power three wire there will be no neutral as you know it. 120 volt equipment will not work. If there is a special berth for 120/240 shore power that is what you will need to tie up to.


Does 240 volt have a neutral wire?

Yes &lt;&lt;&gt;&gt; In North America, a three wire 120/240 volt system uses a neutral wire. For 240 volts two "hot" wires are used with no neutral.


How do you wire a L14-30 female to 2 r-15 male plugs?

You can't do that. An L14-30 is a 240/120 outlet and you cannot "make" 240 volts from two separate plugs; you have to have a hard-wired 240-volt source (either another type of outlet or wired directly to 240 volts).


How do you change a 110 socket outlet into a 210 socket outlet?

You probably mean to change it to a 240 V outlet... either case, you'll need to run a new wire and install a new breaker.


What is four-fifths of three hundred?

240


Will GFCI work properly if 240 volt split into one 3 wire 120 volt circuit?

No, a GFCI outlet is designed for use with standard 120-volt circuits. Attempting to use a GFCI outlet with a 240-volt split circuit could cause damage to the outlet, the circuit, and could present a safety hazard. It is not recommended to use a GFCI outlet in this manner.


What is a four prong outlet used for?

There are a couple of catagories for plug descriptions. Straight blade and twist lock blade. The amperage and voltage rating is embossed on the plug (trade name for plug is cap, wall part receptacle). See related links for a chart.