Several different factors must always be considered when deciding the correct wire size to use:

  • amperage, which is the current to be supplied, measured in amps?
  • length of wire-run?
  • installation situation/site conditions?
    • run inside a conduit?
    • exposed to the air fixed to a wall?
    • extreme heat?
    • damp conditions?
    • underground?

To get the right answers refer to the Wiring Codes or Regulations for your locality. (Town/State.)

<><><>

A #6 copper wire with an insulation factor of 75 or 90 degrees C is rated at 65 amps.

<<>>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

βˆ™ 14y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

βˆ™ 5mo ago

For a 60 amp circuit, it is recommended to use at least a 6-gauge wire to ensure safe and efficient operation. This wire size can handle the current without overheating and causing any potential hazards in the electrical system. Make sure to consult local electrical codes and regulations before selecting the wire gauge for the specific application.

This answer is:
User Avatar

User Avatar

Wiki User

βˆ™ 15y ago

A 60 amp circuit would normally have a #6 size wire, which is what is normally run for a stove, which is typically on a 50 amp 2 pole breaker for the normal home stove. The distance of the wire run might require a bigger size wire if it is very long.

This answer is:
User Avatar

User Avatar

Wiki User

βˆ™ 14y ago

A #6 wire with an insulation factor of 75 or 90 degrees C is rated at 65 amps. In Canada the use of TW 60 degree wire is going out of style due to the inability of the thremoplastic insulation to stand up in cold weather. Below -5C any flexing of the wire cracks the insulation.

Probably not an adequate size. Most residential application terminations are not rated for 90 degrees. and should use the 60 degree values, which make 6 copper good for about 50 amps.

This answer is:
User Avatar

User Avatar

Wiki User

βˆ™ 12y ago

A #6 copper conductor with an insulation factor of 75 and 90 degrees C is rated at 65 amps.

A #4 aluminium conductor with an insulation factor of 75 and 90 degrees C is rated at 65 amps.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What gauge wire is best to use for 60 amps?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

What gauge wire would you use to wire a 120V 20A motor?

For a 120V 20A motor, you would typically use a 12-gauge wire to ensure it can handle the current without overheating. This wire size is suitable for the amperage and voltage to provide proper insulation and safe operation for the motor.


Can you use 8 gauge wire with a 50 amp breaker?

No, an 8 gauge wire is typically rated for a maximum of 40 amps. It is important to match the wire gauge with the appropriate amperage to prevent overheating and potential fire hazards. In this case, you would need to use a thicker wire gauge, such as 6 gauge, for a 50 amp breaker.


What is the max safe amps for 14 gauge wire?

The maximum safe amperage for 14 gauge wire is typically around 15 amps in most household wiring applications. Exceeding this amperage could lead to overheating of the wire and pose a fire hazard. It's important to always verify the specific requirements with the National Electrical Code or a qualified electrician for your specific application.


What can you use 10 gauge wire for?

ten gauge wire is used for high current circuits. in home wiring, 12 gauge wire is normally used. 12 gauge wire can carry a maximum of 20 amps. 10 gauge wire on the other hand, is larger and can carry more current. the maximum current capacity of a 10 gauge wire is around 30 amps. one would use this for a stove, hvac or other power hungry device's.


What gauge wire do you use for 15 amps 200 feet?

For a 15 amp circuit over 200 feet, it is recommended to use a 14-gauge wire to ensure proper voltage drop. This gauge wire will help maintain the integrity of the electrical supply over that distance.

Related questions

What size USE wire is needed for 200 amps?

As a service entrance wire you need AWG # 3/0 gauge copper.


What gauge wire would you use to wire a 120V 20A motor?

For a 120V 20A motor, you would typically use a 12-gauge wire to ensure it can handle the current without overheating. This wire size is suitable for the amperage and voltage to provide proper insulation and safe operation for the motor.


What is amp rating of 14 gauge wire?

In normal residential use it is 20 Amps. That depends on alot of things such as the wire insulation, ambient temperature, etc. Standard NM 12/2 (Romex or equivalent, which is likely what you are asking as it is the primary type used to wire residential) is rated for 20 amps, 14 gauge is 15 amps, 10 gauge is 30 amps.


Can you use 8 gauge wire with a 50 amp breaker?

No, an 8 gauge wire is typically rated for a maximum of 40 amps. It is important to match the wire gauge with the appropriate amperage to prevent overheating and potential fire hazards. In this case, you would need to use a thicker wire gauge, such as 6 gauge, for a 50 amp breaker.


What is the max safe amps for 14 gauge wire?

The maximum safe amperage for 14 gauge wire is typically around 15 amps in most household wiring applications. Exceeding this amperage could lead to overheating of the wire and pose a fire hazard. It's important to always verify the specific requirements with the National Electrical Code or a qualified electrician for your specific application.


What is the proper size wire cord for a 12 amp vacuum sweeper 120 volt?

16 gauge is rated at 13 amps, but I would use 14 gauge which is rated at 15 amps just to be safe.


What gauge of wire must be used in homemade wind turbine?

You would need to know the maximum watts and voltage you could generate then go from there. In home use you use 12 gauge wire at 120 volts to handle up to 20 amps. 14 gauge for 15 amps. If you're operating in 12 volt it's a different ballgame.


What size wire of suitable 13amp motor?

I would recommend you use AWG # 14 gauge which is rated at 15 amps.


What can you use 10 gauge wire for?

ten gauge wire is used for high current circuits. in home wiring, 12 gauge wire is normally used. 12 gauge wire can carry a maximum of 20 amps. 10 gauge wire on the other hand, is larger and can carry more current. the maximum current capacity of a 10 gauge wire is around 30 amps. one would use this for a stove, hvac or other power hungry device's.


What gauge wire do you use for 15 amps 200 feet?

For a 15 amp circuit over 200 feet, it is recommended to use a 14-gauge wire to ensure proper voltage drop. This gauge wire will help maintain the integrity of the electrical supply over that distance.


How many automotive amps can 30 foot strand of copper wire carry?

The number of automotive amps a 30-foot strand of copper wire can carry depends on the gauge (thickness) of the wire. For example, a 30-foot strand of 10-gauge copper wire can typically carry up to 40-50 amps for automotive use, while a 30-foot strand of 12-gauge wire might be limited to around 25-30 amps. It's important to consult wire ampacity tables and consider factors like temperature and voltage drop to ensure safe and effective performance.


What is the max amps for 0 gauge wire?

The maximum amperage of a 0 gauge wire typically ranges from 150 to 200 amps for automotive applications. However, it is important to consult the specific manufacturer's guidelines and consider factors such as temperature and installation conditions to ensure the safe use of the wire.