Yes.
<<>>
No. A #8 conductor with an insulation factor of 75 or 90 degrees C is only rated at 45 amps. You would need a #6 conductor with an insulation factor of 75 or 90 degrees C as it is rated at 65 amps.
Wiki User
∙ 13y agoNo, an 8 gauge wire is typically rated for a maximum of 40 amps. It is important to match the wire gauge with the appropriate amperage to prevent overheating and potential fire hazards. In this case, you would need to use a thicker wire gauge, such as 6 gauge, for a 50 amp breaker.
No, it is not safe to use 10 gauge wire with a 30 amp breaker as the wire is not rated for that high of a current. It is important to use the correct wire gauge that matches the breaker amperage to prevent overheating and potential fire hazards. For a 30 amp breaker, you should use at least 10 gauge wire.
For a stove, use a 8 or 6 gauge wire with a 40 to 50 amp breaker. For a dryer, use a 10 or 8 gauge wire with a 30 amp breaker. For a hot water heater, use a 10 or 8 gauge wire with a 30 or 40 amp breaker. Be sure to consult local electrical codes and guidelines for specific requirements.
No, a 12-gauge wire is typically rated for a 20 amp circuit. To safely handle a 25 amp breaker, you would need to use a 10-gauge wire. It's important to match the wire gauge to the amperage rating of the breaker to prevent overheating and potential fire hazards.
A 14 gauge wire is typically used on a 15 amp circuit breaker. It is not recommended to use a larger circuit breaker with a smaller wire size as this can create a fire hazard.
No, a 12 gauge wire is rated for 20 amps, which matches the breaker size. It is not recommended to use a wire that matches the breaker size as it can result in overheating and potentially cause a fire hazard. Consider using a thicker wire, such as 10 gauge, for the 20 amp breaker to ensure safety for the sub panel.
No, 10 gauge wire requires the use of a 30 amp breaker. A 20 amp breaker is only used on 12 gauge wire.
No. A 20 amp breaker needs 12 gauge wire.
14 gauge will handle it with a 15 amp breaker. If you use 12 gauge use a 20 amp breaker.
No, it is not safe to use 10 gauge wire with a 30 amp breaker as the wire is not rated for that high of a current. It is important to use the correct wire gauge that matches the breaker amperage to prevent overheating and potential fire hazards. For a 30 amp breaker, you should use at least 10 gauge wire.
Normally it is a 20 amp using AWG 12/2 gauge wire. But it really depends on what size wire is on that circuit. If it is white AWG 14 gauge then use a 15 amp breaker. If it is yellow AWG 12 gauge then use a 20 amp breaker.
Use AWG 12/2 with ground.
A 30 amp breaker run 75 feet would require you use AWG #10 wire. But, an oven normally pulls more that 30 amps and I would not use #10 wire on a 30 amp breaker for an oven. Normally any newer oven is wired with AWG #6 gauge wire on a 50 amp circuit breaker so the breaker will not trip during heavy use of the oven. Some older ovens could use a #8 wire on a 40 amp breaker.
No, you should not run 8 gauge wire on a 50 amp breaker. The wire size should be compatible with the amperage rating of the breaker to ensure safety and prevent overheating. For a 50 amp breaker, you should use a minimum of 6 gauge wire.
No, you should not use 10 gauge wire with a 30 amp dryer. A 30 amp dryer requires a minimum of 10 gauge wire, but it is recommended to use 8 gauge wire to ensure safety and to meet electrical code requirements. Using 10 gauge wire may cause overheating and pose a fire hazard.
For 6 gauge wire, typically you would use a 60 amp breaker for larger appliances like a dryer or cooktop. However, always consult with a licensed electrician to ensure the proper breaker size for your specific application and local electrical code requirements.
No, a 12 gauge wire is rated for 20 amps, which matches the breaker size. It is not recommended to use a wire that matches the breaker size as it can result in overheating and potentially cause a fire hazard. Consider using a thicker wire, such as 10 gauge, for the 20 amp breaker to ensure safety for the sub panel.
Depends on the wire size used in the circuit. If you use AWG # 14 wire you must use a 15 amp breaker. If it is wired with AWG # 12 wire then you use a 20 amp breaker. If a AWG # 10 wire is used then a 30 amp breaker is required. The breaker protects the wiring from overheating so you must use the proper size breaker for the wire used.