AWG # 14

User Avatar

Wiki User

βˆ™ 10y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

βˆ™ 6mo ago

For a 5 amp load at 120VAC, you can use a 18-gauge wire for general use. However, it's always recommended to consult local electrical codes or a professional electrician to ensure proper wire sizing for safety.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is wire size for 5 amp 120VAC load?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What wire size will carry a 40 amp load?

AWG # 8


What size electric wire for 28 amp load?

AWG # 10


What size of wire should you used to 10 amp load?

2.5 squre mm


What wire size needed for 120 volt 3000 watt load?

AWG # 10 wire on 30 amp circuit.


What is the cable size required for a 250 amp and 160 amp load?

For a 250 amp load, a cable size of at least 3/0 AWG (American Wire Gauge) or 70mm^2 is recommended. For a 160 amp load, a cable size of at least 1/0 AWG (American Wire Gauge) or 50mm^2 is recommended. It is important to consult local electrical codes and regulations to ensure compliance.


What size hot wire do you need for a 1900 watt amp?

A 12 gauge wire can support a load of approximately 2200 watts.


How do you choose the right fuse for the job?

The correct size fuse needed is based on the size wire used in the circuit. The size wire needed is based on the load that will be applied to the circuit. 1. AWG 14/2 wire = 15 amp fuse 2. AWG 12/2 wire = 20 amp fuse 3. AWG 10/2 wire = 30 amp fuse 4. AWG 8/2 wire = 40 amp fuse


What size Aluminum wire will carry 50 Amp load?

For a 50 Amp load, a 6-gauge aluminum wire would be suitable for most installations. It is important to consult local electrical codes and regulations to ensure compliance with safety standards.


Can you use 3 amp wire on 0.022 amp transformer?

Yes, as long as the load attached to the wire does not exceed 0.022 amps.


How is a hot water heater wired from the power source to the heater?

10/3 wire with 30 amp double pole breaker from panel box to water heater.


How do you determine the size of electrical conductors?

by the size of the load they are connected to. a general lighting circuit in a home should be 500 sq feet. an appliance will have it's connected load on the name plate. all electrical components [ plugs, cord, wire, anything electricity flows through] must be DERATED 20 %. if your load is 30 amp 240, add 6 amp[20%]to the 30, for 36amp. the closest wire size is #8.


What size wire do i need to feed a single phase V primary and a V secondary fed from a 150 amp circuit breaker?

Information is incomplete. You need to know the load in Watt or Kilowatt and the voltage on the secondary side to determine the load current, on which the size of the wire is designed.