Answer for USA, Canada and countries running a 60 Hz supply service.

There is a device that you can pick up from a DIY store. Ask the clerk to show you their duplex breakers. The one that you should be looking for is a 15-30-30-15. This will allow you to remove two 15 amp existing breakers and install this new one. The two existing 15 amp circuit loads will be connected to the new 15 amp positions on the new breaker. Your required 30 amp load will be connected to the center position on the new breaker.

<<>>

It depends on what you mean by the breaker panel being full. It depends on the equipment involved and would require more detailed information about the existing electrical panel.

If you don't know the answer, contact a licensed electrician.

<><><>

Take two breakers out of the box and add a high power 240 volt circuit. Run that to a subpanel, and add the breakers (including the two you took out) to the subpanel.

Remember that the safety ground and the neutral must be kept completely separate in the subpanel.

<><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,
on electrical circuits, equipment or appliances,
always use a test meter to ensure the circuit is, in fact, de-energized

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

15y ago

What else can I help you with?

Continue Learning about Natural Sciences

Can a 200A 240V house panel be fed by number 2 conductors from a service entrance meter panel with 200A main breaker?

No, number 2 conductors are not sufficient to carry 200A. You would need larger gauge wires to safely handle that amount of current. It is important to match the wire size to the amperage rating of the panel to prevent overheating and potential hazards.


How do you wire a 15 amp 120V breaker in a 240v 30 amp breaker panel?

Look to see if the 30 amp panel is fed with a two wire or a three wire. If it is a two wire then you are out of luck. If the panel is fed with a three wire then the panel should have the neutral terminated in the panel. It is this neutral that you need for 120 volt connections. You didn't state how many panel slots there are in the panel. If you are able install a 15 amp breaker into the panel and connect the wires going to the load. The black wire will go to the breaker and the white wire will go to the neutral bar in the panel.


Can GFCI circuit breaker handle a 240V circuit with a 120V circuit sub-paneled off if it?

I don't know if you are trying to ask if you can run a 240V panel off a GFCI or run a 120 V sub panel off of a GFCI. Can you clarify please,,,Thanks


How many 30amp slots in a breaker box are needed for 240v cook top?

You would need one 30 amp double-pole breaker in the breaker box for a 240V cooktop.


If you install a 30A 240V GFI breaker will this be ok or will the cycles the dryer has prematurely fail the breaker?

Installing a 30A 240V GFI breaker for a dryer should be fine as long as the wiring and dryer itself are compatible with the breaker. The GFI breaker is designed to protect against electrical faults and should not be affected by the cycles of the dryer. Make sure to follow the installation instructions carefully to ensure proper functioning.

Related Questions

Can a 200A 240V house panel be fed by number 2 conductors from a service entrance meter panel with 200A main breaker?

No, number 2 conductors are not sufficient to carry 200A. You would need larger gauge wires to safely handle that amount of current. It is important to match the wire size to the amperage rating of the panel to prevent overheating and potential hazards.


How do you wire a 15 amp 120V breaker in a 240v 30 amp breaker panel?

Look to see if the 30 amp panel is fed with a two wire or a three wire. If it is a two wire then you are out of luck. If the panel is fed with a three wire then the panel should have the neutral terminated in the panel. It is this neutral that you need for 120 volt connections. You didn't state how many panel slots there are in the panel. If you are able install a 15 amp breaker into the panel and connect the wires going to the load. The black wire will go to the breaker and the white wire will go to the neutral bar in the panel.


How much voltage should be in 2pole circuit breaker?

In America, a 2-pole breaker is controlling 240V. 120V per leg.


Considering 100A 240V service has 2 poles at 100A each is the total usable power actually 200A at 120V?

No, amperage is not additive, but a constant. Think of power as water, its always the same temperature, hot (amps). The pressure is variable (volts). The true answer is undoubtedly more complex, but you get the point. If you need to draw 200 amps you would actually need a 400 amp service because code states you cannot have more than an 80% load on a breaker That's an interesting question and I had to run the theory through my brain a few times to confirm my answer. The answer is if you have a 100A 240V service, you could draw what appears to be 200A from that panel at 120V. If you install 100A 120V single pole breakers on each side of the panel (in reality this would be many breakers but let's keep it simple) then both breakers will operate just fine, giving the appearance of 200A. In reality, however, one breaker actually feeds through to the other breaker. The neutral only carries the unbalanced load so in this hypothetical situation the neutral at the panel carries 0A. So the answer to the question is...if you install ONLY 120v single pole breakers, you can run up to 200A on those circuits (or 80% of that as we have discussed.) But you are only running 100A on each leg of the service conductors and breaker.


Can GFCI circuit breaker handle a 240V circuit with a 120V circuit sub-paneled off if it?

I don't know if you are trying to ask if you can run a 240V panel off a GFCI or run a 120 V sub panel off of a GFCI. Can you clarify please,,,Thanks


What are the steps in connecting 120V to a 240V 60A air condition panel?

you should have three wires into the panel. two of them go to the double breakers or pull switch and the last is the ground lead. You can pick up 110 vac from one side of either breaker and that ground connection. DO NOT connect to the both breaker wires as that will be 220 vac


What is the maximum voltage capacity of a 240V single pole breaker?

The maximum voltage capacity of a 240V single pole breaker is 240 volts.


How do you properly wire a double pole breaker for 240v?

To properly wire a double pole breaker for 240V, connect the two hot wires to the breaker terminals, the neutral wire to the neutral bus bar, and the ground wire to the ground bus bar in the electrical panel. Make sure to follow the manufacturer's instructions and local electrical codes for safety.


How many 30amp slots in a breaker box are needed for 240v cook top?

You would need one 30 amp double-pole breaker in the breaker box for a 240V cooktop.


If you install a 30A 240V GFI breaker will this be ok or will the cycles the dryer has prematurely fail the breaker?

Installing a 30A 240V GFI breaker for a dryer should be fine as long as the wiring and dryer itself are compatible with the breaker. The GFI breaker is designed to protect against electrical faults and should not be affected by the cycles of the dryer. Make sure to follow the installation instructions carefully to ensure proper functioning.


What is the maximum current capacity of a 30 amp breaker for a 240v circuit?

The maximum current capacity of a 30 amp breaker for a 240v circuit is 30 amps.


What is the recommended AC breaker size for a 240V air conditioning unit?

The recommended AC breaker size for a 240V air conditioning unit is typically 20 amps.