A dryer requires a 30 amp receptacle. This will be to receive a four blade dryer plug. The wire needed will be a three copper wire #10 cable set with a bare #14 copper ground wire. The breaker will be a two pole 30 amp breaker.
You never, ever mix wire sizes within a circuit. However you can wire a 30 amp circuit using AWG # 8/3 wire, although that is overkill and AWG #10 wire is what you would normally use on a 30 amp circuit.
the size of the wire that you need to run depends on the the amperage of the device/appliance you'll be hooking up to that line. Use #12 wire for 20 amp, #10 for 30 amp, #8 wire for 40 amps and #6 for 50 amps. Hope that helps.
#10 wire is used on a 30 amp service.
A 30 amp breaker run 75 feet would require you use AWG #10 wire. But, an oven normally pulls more that 30 amps and I would not use #10 wire on a 30 amp breaker for an oven. Normally any newer oven is wired with AWG #6 gauge wire on a 50 amp circuit breaker so the breaker will not trip during heavy use of the oven. Some older ovens could use a #8 wire on a 40 amp breaker.
Typically yes if you use a 30 amp breaker and the dryer uses 230-240 volts.
A dryer requires a 30 amp receptacle. This will be to receive a four blade dryer plug. The wire needed will be a three copper wire #10 cable set with a bare #14 copper ground wire. The breaker will be a two pole 30 amp breaker.
If you are referring to a cloths dryer, the answer depends on the requirements of the dryer. Most dryers require AWG#10 wire with a 30 amp fuse. If the wiring is AWG#12 then use a 20 amp breaker but never use it on AWG#10 which requires a 30 amp breaker. If you are referring to a hair dryer then yes a 20 amp breaker is fine.
No !
no. depending on length of run you'll need either 10 or 6 gauge wire for a 30 amp double pole breaker.
If your breaker box will accept tandom breakers you can remove 4 single pole breakers add 2 tandoms this will empty 2 spaces for your 2 pole 30 amp for the dryer
Typical residential electric dryers are on 30 amp circuits, which means 10 gage copper wire. The circuit breaker should match the dryer cord rating, generally 30 amps.
You can do a 30 amp twist lock receptacle 220v 3 wire (nema L6-30R) or a strait blade 30 amp 220v 3 wire receptacle (nema 6-30R) or a traditional 30 amp dryer plug. The nema # is a universal # that everyone uses to identify that plug. Ask for it. The most important part is the 30 amp male that your trying to plug in. Match it up with what you putting in the wall. Use #10 gauge wire for 30 amps
yes
60 amps is twice the amount that you need for a household dryer. What you need is a two pole 30 amp breaker feeding a three conductor #10 cable. A dryer needs a neutral wire, hence the three wire cable for a 240 volt device.
I am guessing that the dryer is 220-240 VAC as is the compressor. I also assume that the third wire on the dryer is a ground. You need to make sure that the metal chassis on the compressor is not connected to the two wires. You then need to create a covered junction box where you have the two existing wires and a ground wire that you connect to the compressor metal chassis with a screw type connector. Ground wire should be 10 AWG. Now you have three wires. Connect the two hot wires of supply to two original wires on compressor and ground wire to the chassis ground.
It's necessary to look at the dyer to see how much current it uses, which should be on the maker's plate near where the cable enters the appliance. If it uses less than 50 amps, a 50 amp cable is all right.