Best Answer

== == == == Don't know if there are any 240V GFCI receptacles so I vote for a 240V GFCI breaker which would be 2 pole. The pump should have two colored wires and a white. White goes to the neutral bus and the two colored wires go to the two poles of the breaker. <><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed. Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

14y ago

Black to black, white to white and ground to green terminal on the pump.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you wire a 3-wire 240V 15A pump motor to a GFCI receptacle or GFCI breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can I run a double 30 amp breaker with 10-3 wire to receptacle for 240v MIG welder. Distance from main box to destination is 60 feet.?

Yes.


How do you run dedicated 240V lines for power tools?

Answer for USA, Canada and countries running a 60 Hertz supply service.One 240 volt receptacle fed from a two pole breaker from the distribution panel. The size of the breaker is determined by the load current and the wire sized accordingly.


240v box outside for a hot tub you need a 110v receptacle Can you wire it off the 240v box?

Using a box that is hire voltage than what you need can cause a short, and even a fire. So using a 240V box, when all you need is a 110v receptacle, wouldn't be a good idea.


Why would someone use two positive wires to complete a house 2 plug receptacle circuit?

If the 2 hot wires are connected to either side of a receptacle, you have a 240v receptacle (assuming it's in the US). This is typically done for window air conditioners. But code requires that the receptacle have a different configuration than other receptacles in the building so you don't run the risk of plugging in a 120v device into a 240v receptacle.


How can you wire one half of a 20 amp 120 v duplex wall socket to run 240 volts over 2 legs 2 separate 120 v legs?

You can't. I'm not sure exactly what you're trying to do, but the way it is written is not possible. It seems you might want to use half of a duplex receptacle for 120 and half for 240. This would not be code compliant, nor would it make sense. A plug designed for 240v will not even fit into a 120v receptacle. You need a 240 volt receptacle rated for the amperage you will need. Also, an existing 120v receptacle has nothing to do with your 240v receptacle. For a 240 volt receptacle, you'll need to run 2 new 120v lines (in the same cable). The existing 120v circuit cannot be used here, even if you added another 120v circuit, because when a load uses 240v, both 120v circuits supplying the 240v must be controlled by a common disconnect (a 2 pole breaker designed for 240v circuit). My advice would be to show an electrician what you want done. I'm sure they can tell you how to make that happen.


If you install a 30A 240V GFI breaker will this be ok or will the cycles the dryer has prematurely fail the breaker?

I suspect you mean GFIC breaker. The dryer will not cause the breaker to fail.


What is breaker size for 240 volt 9 KW?

The formula you are looking for is I = W/E.


Can I replace a 50 amp 240v dryer outlet with a std 15 amp 240 volt outlet?

Theoretically yes if you remove the two pole 50 amp breaker and replace it with a 2 pole 15 amp breaker. This has to be done because the new receptacle is only rated at 15 amps and can not be protected by a breaker any larger than 15 amps.Physically this is not going to happen due to the fact that you will not be able to connect the existing #6 conductor, which fed the 50 amp dryer receptacle, under the terminals of the new 2 pole 15 amp breaker.


How can you plug 2000 watts 240v into a 120v 20 amp breaker with out replacing your breaker and all the plugs on the line?

You can't.


How do you safely connect to a 240V pullout fuse box used for pool equipment located in a detached garage as a temporary power source for a 240V millermatic 250 mig welder?

The voltage is correct, BUT, Your welder is going to draw more current than the pool pump did. The breaker, wiring, and the receptacle will have to be upgraded. In my opinion I have never seen a "temporary" connection!! ...pkazsr


How much voltage should be in 2pole circuit breaker?

In America, a 2-pole breaker is controlling 240V. 120V per leg.


How do you run a 120V outlet off a 240V water well breaker?

You will need to have a three wire feeding your well pump motor to do this. It will be connected like a sub panel breaker box. A new breaker for the pump out of the new panel and a 15 amp breaker for the new receptacle. Both of these circuits must be protected by their own breaker. As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed. Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized. IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.