A breaker trips when there is too much current. If you unplug everything on the circuit and the breaker still trips then you have a wiring problem or a bad breaker. From your description it is not possible to be certain if the problem started when you installed new outlet or previously. You have to describe your problem in better detail to get a good answer. When you have a circuit that trips the corresponding breaker, you need to go through each outlet on the circuit and rule it out as the problem. This can be done by pulling each outlet, from the wall and systematically remove wires from outlets while power is off and determining when problem goes away.
A bad circuit breaker. Replace it.
I do not even know that it is the light switch that is popping your circuit breaker! It may be the switch or something else. The light switch controls a circuit. As electricity passes through that circuit it is heating up a contact or a weak place in a wire. At a certain point that hot place in a connector or in a wire allows the electricity to jump out of the circuit and not go through the light. When that happens, the circuit breaker pops. You can turn off the circuit breaker. Then you can look at the connectors on your light switch. If one of them looks burned, You have solved the problem. You replace the light switch. Next comes the more difficult task of looking at the connectors for your lamp. If they are not easy to get to, you call an electrician.
No. The breaker must protect the circuit components such as wiring, outlets and switches that are connected to the breaker. Therefore if you have a 30 amp circuit as dictated by its components you need to protect it with a 30 amp or less breaker.
The breaker will have a black wire connected to it. Turn off the main breaker and then disconnect that black wire from the breaker. The breaker will snap into the main bar. Remove the breaker and install the new one. Reconnect the black wire to the breaker and then install the cover and turn the main breaker back on.
Siemens type P, ITE as well
You can reset a circuit breaker but a fuse you must replace.
A bad circuit breaker. Replace it.
No.
You should replace the surge strip if the circuit breaker fails to reset.
Replace it immediatly, the breaker is no longer within code.
A circuit breaker is designed to 'break' in a circuit if a short circuit (or other malfunction) occurs. This prevents overheating (or burn-out) of the circuit wires. In older systems, you would need to find which fuse wire has fused and replace it. In a circuit breaker, once the fault has been found and corrected, the breaker is simply switched back on.
Replace the 30 Amp Breaker with a 15 Amp breaker.
I do not even know that it is the light switch that is popping your circuit breaker! It may be the switch or something else. The light switch controls a circuit. As electricity passes through that circuit it is heating up a contact or a weak place in a wire. At a certain point that hot place in a connector or in a wire allows the electricity to jump out of the circuit and not go through the light. When that happens, the circuit breaker pops. You can turn off the circuit breaker. Then you can look at the connectors on your light switch. If one of them looks burned, You have solved the problem. You replace the light switch. Next comes the more difficult task of looking at the connectors for your lamp. If they are not easy to get to, you call an electrician.
No. The breaker must protect the circuit components such as wiring, outlets and switches that are connected to the breaker. Therefore if you have a 30 amp circuit as dictated by its components you need to protect it with a 30 amp or less breaker.
The breaker will have a black wire connected to it. Turn off the main breaker and then disconnect that black wire from the breaker. The breaker will snap into the main bar. Remove the breaker and install the new one. Reconnect the black wire to the breaker and then install the cover and turn the main breaker back on.
Usually it means to blow it, it broke - you need to flick a breaker or replace it as it blew.
It is built into the switch and is not serviceable. You will have to replace the switch assembly.