Answer for USA, Canada and countries running a 60 Hz supply service.

500 mcm wire is a stranded wire with the equivalent of 500,000 circular mils in cross-sectional area.

A circular mil is a circle with a diameter of 1 mil, or 1/1000th of an inch.

500 kcmil means the same thing.

In common practice this size conductor is capable of handling 400 amps.

<><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is 500 mcm wire amp rating?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the amp rating of 500mcm?

500 MCM can carry 380 Amps at 75 degrees C.


What size wire is required for 325 amp service?

A 350 MCM copper conductor with an insulation rating of 90 degree C is rated at 350 amps.


What is the amperage rating of 800 MCM Copper wire?

600amps


What size ground do you need for 4000 amp service?

500 mcm


What is the amperage rating of 500 MCM copper conductor?

It depends on a lot of factors. Generally speaking, if the insulation is THHN then the rating is 350 amps. If the insulation is THWN then the rating is 310 amps. The ampere rating for wire depends on the temperature of the environment it will be used in, the insulation rating and the number of circuits installed in a conduit. There are also other factors to consider... like voltage drop in long runs.


Wire size for 500 Amp service?

000 &lt;&lt;&gt;&gt; A 750 MCM copper conductor with an insulation factor of 90 degrees C is rated at 500 amps.


What size wire is needed for 1600 amp service?

4 sets of 750 mcm aluminum. Or four parallel runs of 600 MCM copper.


Can you run 500mcm to feed 480 volt 400 amp service?

500 mcm (or 500kcmil) conductors are used for 400 amp 480v single phase or 3 phase systems. The wire AND THE TERMINALS must be rated for 90o Celsius.


You want guide on how to find amp 14 to 700 mcm wire?

yeah sure ill have 1


If you have a 400 Amp service using 500 MCM What size grounding electrode conductor is required?

#2


For a parallel feed to a 1200 Amp service 3 phase what size is the grounding electrode to main service with 3 600 mcm parallel runs?

500 mcm


What gauge is 500 amp cable?

A 750 MCM copper conductor with an insulation factor of 90 degrees C is rated at 500 amps.