A dryer requires a 30 amp receptacle. This will be to receive a four blade dryer plug. The wire needed will be a three copper wire #10 cable set with a bare #14 copper ground wire. The breaker will be a two pole 30 amp breaker.
You never, ever mix wire sizes within a circuit. However you can wire a 30 amp circuit using AWG # 8/3 wire, although that is overkill and AWG #10 wire is what you would normally use on a 30 amp circuit.
the size of the wire that you need to run depends on the the amperage of the device/appliance you'll be hooking up to that line. Use #12 wire for 20 amp, #10 for 30 amp, #8 wire for 40 amps and #6 for 50 amps. Hope that helps.
#10 wire is used on a 30 amp service.
A 30 amp breaker run 75 feet would require you use AWG #10 wire. But, an oven normally pulls more that 30 amps and I would not use #10 wire on a 30 amp breaker for an oven. Normally any newer oven is wired with AWG #6 gauge wire on a 50 amp circuit breaker so the breaker will not trip during heavy use of the oven. Some older ovens could use a #8 wire on a 40 amp breaker.
The recommended wire size for a 30 amp dryer circuit is typically 10 gauge wire.
No, you should not use 10 gauge wire with a 30 amp dryer. A 30 amp dryer requires a minimum of 10 gauge wire, but it is recommended to use 8 gauge wire to ensure safety and to meet electrical code requirements. Using 10 gauge wire may cause overheating and pose a fire hazard.
For a dryer installation, it is recommended to use a wire gauge of 10 AWG (American Wire Gauge) for a 30-amp circuit or 8 AWG for a 40-amp circuit.
A dryer requires a 30 amp receptacle. This will be to receive a four blade dryer plug. The wire needed will be a three copper wire #10 cable set with a bare #14 copper ground wire. The breaker will be a two pole 30 amp breaker.
If you are referring to a cloths dryer, the answer depends on the requirements of the dryer. Most dryers require AWG#10 wire with a 30 amp fuse. If the wiring is AWG#12 then use a 20 amp breaker but never use it on AWG#10 which requires a 30 amp breaker. If you are referring to a hair dryer then yes a 20 amp breaker is fine.
No !
The proper electrical setup for a 30 amp dryer outlet requires a dedicated 30 amp circuit breaker, 10-gauge wire, and a 3-prong or 4-prong dryer outlet. It is important to follow the National Electrical Code and consult a licensed electrician for installation.
no. depending on length of run you'll need either 10 or 6 gauge wire for a 30 amp double pole breaker.
The recommended amperage for a breaker to use with a 30 amp dryer is 30 amps.
I am guessing that the dryer is 220-240 VAC as is the compressor. I also assume that the third wire on the dryer is a ground. You need to make sure that the metal chassis on the compressor is not connected to the two wires. You then need to create a covered junction box where you have the two existing wires and a ground wire that you connect to the compressor metal chassis with a screw type connector. Ground wire should be 10 AWG. Now you have three wires. Connect the two hot wires of supply to two original wires on compressor and ground wire to the chassis ground.
Typical residential electric dryers are on 30 amp circuits, which means 10 gage copper wire. The circuit breaker should match the dryer cord rating, generally 30 amps.
For a stove, use a 8 or 6 gauge wire with a 40 to 50 amp breaker. For a dryer, use a 10 or 8 gauge wire with a 30 amp breaker. For a hot water heater, use a 10 or 8 gauge wire with a 30 or 40 amp breaker. Be sure to consult local electrical codes and guidelines for specific requirements.