Black/White/Ground power in and the same out. Tie the incoming and outgoing white wires together under a yellow wire nut and push them back in the box. Tie the ground wires together under a green wire nut and connect the pigtail from those ground wires to the ground screw on the switch. Connect the 2 black wires you have left to the 2 screws on the switch. Doesn't matter which black wire you connect to which screw.
Chat with our AI personalities
The well pump breaker is installed in two slots in your breaker box. You then run the correct size cable for the amperage of the pump to the area where the pressure tank is located. install a breaker or disconnect on the wall near the pressure tank and then connect the low pressure switch to the disconnect. Connect the pump to the low pressure switch.
I think you mean 2 HP pump. I am assuming a 220 To 240 volt supply and that should equate to about a 12 amp current. All my pumps use only a 30 amp breaker and 10 AWG wire.
A #14 copper wire rated at 15 amps is the minimum size wire for a 15 amp receptacle.
Depends on the wire size you are using. If the generator breaker is a 30 amp then install a 30 amp breaker.
Replacement for American Switch single pole 15 amp circuit breaker