A 30-A outlet would be for a specialized installation, such as for a welder or other high-wattage device. You would typically have a single outlet, although you could certainly have multiple outlets for convenience, as long as there were procedures to prohibit use of more than one at a time.

Under no circumstances should any HOUSEHOLD receptacles (15 or 20-Amp) be installed on any branch protected by a 30-amp breaker, as this would cause a fire and electrocution hazard.

User Avatar

Wiki User

12y ago

Still curious? Ask our experts.

Chat with our AI personalities

ReneRene
Change my mind. I dare you.
Chat with Rene
JordanJordan
Looking for a career mentor? I've seen my fair share of shake-ups.
Chat with Jordan
EzraEzra
Faith is not about having all the answers, but learning to ask the right questions.
Chat with Ezra
More answers

15 amps x120 volts =1800 watts. NEC requires you not exceed 60% of the load. Therefore 1800 x .60 =1080. 1080 watts divided by 120 volts = 9. You can safely install 9 outlets on each 15 amp circuit but no more. This is assuming only those 9 outlets will be on the circuit and no lights.

User Avatar

Wiki User

11y ago
User Avatar

You should install no more than 9 outlets. If you add a 75 watt light then install no more than 8 outlets and that 1 light.

User Avatar

Wiki User

11y ago
User Avatar

Add your answer:

Earn +20 pts
Q: How many outlets and light can you put on a 15amp circuit breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

How many 50 watt lights on a 15 amp circuit?

50 watt equals less than 1/2 amp current flow at 120 volts so you can have 30 light on a 15amp breaker or 40 on a twenty amp breaker.


How many eletrcal outlets can you have in a garage?

There is no limit as to the amount of circuits you can have in a garage. If you mean how many devices on a 15 amp single circuit breaker then the answer is 12. Be sure to total in light fixture outlets and switch boxes.


How many outlets are allowed on a 240 v branch circuit?

Branch circuit loading In Canada the CEC states that there shall be not more than 12 outlets on any 2-wire branch circuit. These outlets shall be considered to be rated at not less than 1 amp per outlet Where the connected load is known, the number of outlets shall be permitted to exceed 12, provided that the load current does not exceed 80% of the rating of the over current device protecting the circuit. For example on a 15 amp breaker, 15 x 80% = 12 amps, hence the standard of 12 outlets on any 2-wire branch circuit. On a 20 amp breaker, 20 x 80% = 16 amps. So from a 20 amp breaker this allows 16 outlets on a 2-wire branch circuit as long as the outlets are not considered to be rated at less than 1 amp per outlet. The definition of an outlet is a point in the wiring installation at which current is taken to supply utilization equipment. What this means is that if a light switch and a fixture outlet were on the same 2-wire branch circuit they would be subtracted from the maximum count of 12 receptacle outlets on the circuit which would leave 10. If the light fixture draws 3 amps plus the switch outlet, then the total circuit outlet count would be reduced to 8 receptacle outlets (12 -- 3 -- 1 = 8). On a standard specification home most electricians will wire one circuit per room, the outlet count usually never reaches the maximum of 12 outlets.


How many outlets can you have on one circuit?

Depends on what the outlets are controlling, size of the wire, and size of the breaker.


What are the electrical codes covering - wiring a new garage?

Depends on what you are asking about. I can tell you that all garage outlets must be protected by a GFCI circuit. You can install as many or as little as you want as long as there is at least 1 outlet on each wall. Any freezer or refrigerator must be on a dedicated circuit. There must be a light switch by the doorway mounted 48" to the top of the switch box. If you have 2 entrances into the garage then install a 3 way light switch so the lights can be turned on/off at both locations. Outlets cannot me mounted higher than 48" above the floor. I would install the outlets on 1 circuit and the lights on another circuit unless you only have a couple of lights. Use AWG #12 wire for the garage protected by a 20 amp breaker. If the garage is detached from the house then you need a disconnect in the garage. Any 240 volt outlet must be on a dedicated circuit protected by the proper breaker and correct size wire needed for the device.