A 30-A outlet would be for a specialized installation, such as for a welder or other high-wattage device. You would typically have a single outlet, although you could certainly have multiple outlets for convenience, as long as there were procedures to prohibit use of more than one at a time.
Under no circumstances should any HOUSEHOLD receptacles (15 or 20-Amp) be installed on any branch protected by a 30-amp breaker, as this would cause a fire and electrocution hazard.
50 watt equals less than 1/2 amp current flow at 120 volts so you can have 30 light on a 15amp breaker or 40 on a twenty amp breaker.
There is no limit as to the amount of circuits you can have in a garage. If you mean how many devices on a 15 amp single circuit breaker then the answer is 12. Be sure to total in light fixture outlets and switch boxes.
Branch circuit loading In Canada the CEC states that there shall be not more than 12 outlets on any 2-wire branch circuit. These outlets shall be considered to be rated at not less than 1 amp per outlet Where the connected load is known, the number of outlets shall be permitted to exceed 12, provided that the load current does not exceed 80% of the rating of the over current device protecting the circuit. For example on a 15 amp breaker, 15 x 80% = 12 amps, hence the standard of 12 outlets on any 2-wire branch circuit. On a 20 amp breaker, 20 x 80% = 16 amps. So from a 20 amp breaker this allows 16 outlets on a 2-wire branch circuit as long as the outlets are not considered to be rated at less than 1 amp per outlet. The definition of an outlet is a point in the wiring installation at which current is taken to supply utilization equipment. What this means is that if a light switch and a fixture outlet were on the same 2-wire branch circuit they would be subtracted from the maximum count of 12 receptacle outlets on the circuit which would leave 10. If the light fixture draws 3 amps plus the switch outlet, then the total circuit outlet count would be reduced to 8 receptacle outlets (12 -- 3 -- 1 = 8). On a standard specification home most electricians will wire one circuit per room, the outlet count usually never reaches the maximum of 12 outlets.
Depends on what the outlets are controlling, size of the wire, and size of the breaker.
Depends on what you are asking about. I can tell you that all garage outlets must be protected by a GFCI circuit. You can install as many or as little as you want as long as there is at least 1 outlet on each wall. Any freezer or refrigerator must be on a dedicated circuit. There must be a light switch by the doorway mounted 48" to the top of the switch box. If you have 2 entrances into the garage then install a 3 way light switch so the lights can be turned on/off at both locations. Outlets cannot me mounted higher than 48" above the floor. I would install the outlets on 1 circuit and the lights on another circuit unless you only have a couple of lights. Use AWG #12 wire for the garage protected by a 20 amp breaker. If the garage is detached from the house then you need a disconnect in the garage. Any 240 volt outlet must be on a dedicated circuit protected by the proper breaker and correct size wire needed for the device.
Your only hope is that someone wired the box not to code and that there are two wires going into the offending breaker. If you can't separate wires you can't distribute the load.
50 watt equals less than 1/2 amp current flow at 120 volts so you can have 30 light on a 15amp breaker or 40 on a twenty amp breaker.
There is no limit as to the amount of circuits you can have in a garage. If you mean how many devices on a 15 amp single circuit breaker then the answer is 12. Be sure to total in light fixture outlets and switch boxes.
If you have a light that is not being powered through a circuit breaker or fuse, you should call a qualified electrician to remove this circuit from the panel's bus and install a circuit breaker for it. Without an overcurrent protective device (circuit breaker or fuse) you have a potential fire hazard.
It means the breaker has been tripped. There are two possible ways to reset it - some have a button on the outlet (there may be several outlets on one circuit, so you may have to look around) the other is the main breaker in your breaker box. You'll need to find a reset the breaker.
The pool light is usually on a 15 amp circuit. The breaker feeding this circuit must have a GFCI rating.
It is recommended to have a maximum of 8 to 10 outlets and lights combined on a 60 amp breaker depending on the power draw of the devices connected. It is important not to overload the circuit to prevent potential hazards such as electrical fires. It is advisable to consult with a qualified electrician to ensure the load on the circuit is within a safe limit.
Utility outlets and lighting outlets should be separate so that when a utilization device plugged into an outlet trips the breaker or blows the fuse, you won't be left trying to find your way to safety in the dark. Light fixtures are much less likely to trip a breaker in ordinary use, but there are places you also want more than one lighting circuit for illumination.
If all outlets in a bedroom and the bathroom light are losing power even after resetting the breaker, there could be an issue with the wiring, a tripped GFCI outlet somewhere in the circuit, a faulty outlet or light fixture, or a more serious electrical problem. It would be recommended to contact a qualified electrician to diagnose and fix the issue to ensure safety.
Branch circuit loading In Canada the CEC states that there shall be not more than 12 outlets on any 2-wire branch circuit. These outlets shall be considered to be rated at not less than 1 amp per outlet Where the connected load is known, the number of outlets shall be permitted to exceed 12, provided that the load current does not exceed 80% of the rating of the over current device protecting the circuit. For example on a 15 amp breaker, 15 x 80% = 12 amps, hence the standard of 12 outlets on any 2-wire branch circuit. On a 20 amp breaker, 20 x 80% = 16 amps. So from a 20 amp breaker this allows 16 outlets on a 2-wire branch circuit as long as the outlets are not considered to be rated at less than 1 amp per outlet. The definition of an outlet is a point in the wiring installation at which current is taken to supply utilization equipment. What this means is that if a light switch and a fixture outlet were on the same 2-wire branch circuit they would be subtracted from the maximum count of 12 receptacle outlets on the circuit which would leave 10. If the light fixture draws 3 amps plus the switch outlet, then the total circuit outlet count would be reduced to 8 receptacle outlets (12 -- 3 -- 1 = 8). On a standard specification home most electricians will wire one circuit per room, the outlet count usually never reaches the maximum of 12 outlets.
When several outlets are on the same circuit the current comes first from the breaker panel to one outlet where it is connected to a duplex receptacle and/or switch or light, then to the NEXT outlet, light or switch. If a connection was not made properly at any point along the way it can corrode or somehow loose connection back to the breaker panel. If that happens, every outlet DOWNSTREAM will not be working properly. If you cannot track down the problem yourself, you will need to hire an electrician.
Branch circuit loading In Canada the CEC states that there shall be not more than 12 outlets on any 2-wire branch circuit. These outlets shall be considered to be rated at not less than 1 amp per outletWhere the connected load is known, the number of outlets shall be permitted to exceed 12, provided that the load current does not exceed 80% of the rating of the over current device protecting the circuit. For example on a 15 amp breaker, 15 x 80% = 12 amps, hence the standard of 12 outlets on any 2-wire branch circuit.On a 20 amp breaker, 20 x 80% = 16 amps. So from a 20 amp breaker this allows 16 outlets on a 2-wire branch circuit as long as the outlets are not considered to be rated at less than 1 amp per outlet.The definition of an outlet is a point in the wiring installation at which current is taken to supply utilisation equipment. What this means is that if a light switch and a fixture outlet were on the same 2-wire branch circuit they would be subtracted from the maximum count of 12 receptacle outlets on the circuit which would leave 10.If the light fixture draws 3 amps plus the switch outlet, then the total circuit outlet count would be reduced to 8 receptacle outlets (12 – 3 – 1 = 8).On a standard specification home most electricians will wire one circuit per room, the outlet count usually never reaches the maximum of 12 outlets.