answersLogoWhite

0

A #6 copper conductor is rated at 65 amps. To connect to a 50 amp RV outlet you will need a four conductor #6 SOW 600 volt cabtire. The black and red wires go on terminals X and Y. The white wire goes on terminal W. The green wire goes on terminal G.

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Electrical Engineering

What is the minimum wire size used in a commercial building?

The minimum size wire that engineers spec for industrial and commercial installations is #12 and it usually is stranded not solid wire.


What are the wires going to outlets called?

The wires going to outlets are typically referred to as "branch circuit conductors." These wires connect the outlet to the electrical panel, supplying power to the outlet for devices and appliances. Common types of wire used for this purpose include NM (non-metallic) cable and conduit wiring, which usually consist of a hot wire, a neutral wire, and a ground wire.


How many wall outlets can you have in a circuit using a A breaker?

Assuming this is not an office of a place where lots of the outlets will be used to power items that draw lots of current on a 15 amp circuit wired with 14/2 wire I would limit it to no more than 10 outlets and lights combined. On a 20 amp circuit wired with 12/2 wire I would limit it to a 14 outlets and lights combined. There is no limit in the code. You just use common sense based on what is going to be used on this circuit.


What is the wire size for 208 volt?

As with any electrical installation, the wire size used depends on the expected maximum current the wire will carry. That cannot be determined by voltage alone.


Why is it necessary to upgrade old electrical outlets?

Older style wires and cables are not as safe as the current types used for house wiring. For example, older insulation becomes brittle with age and can break when the wire is moved. Newer wiring is a lot more flexible and can handle age much better than the old insulation. Newer wiring specifications require that all circuits include a connection to ground, older outlets do not have that requirement. Newer outlets are far safer, not just because of the ground wire but because of the plug polarity that has been introduced to the newer standard.

Related Questions

What is 12 awg?

12 AWG stands for American Wire Gauge 12, which is a standard measurement of the diameter of electrical wire. It indicates a wire with a diameter of 0.0808 inches and is commonly used for household electrical wiring, outlets, and switches.


Can 14-2 wire be used for outlets?

Yes, 14-2 wire can be used for outlets in residential settings. The 14-2 wire consists of a black (hot), white (neutral), and bare copper (ground) conductor. It is suitable for circuits with a 15-amp breaker and can safely power standard outlets.


What wire should be used for outlets?

For outlets, it is recommended to use 12-gauge wire for 20-amp circuits and 14-gauge wire for 15-amp circuits.


Can I use 12/2 wire for outlets in my electrical installation?

No, it is not recommended to use 12/2 wire for outlets in your electrical installation. It is typically used for lighting circuits and not outlets, which usually require 14/2 or 12/3 wire for proper installation.


Can 14-2 wire be used for outlets in a residential electrical installation?

No, 14-2 wire is typically used for lighting circuits in residential electrical installations. For outlets, it is recommended to use 12-2 wire to handle the higher electrical load.


What size of wire use if you have 6 outlet with 30 amp breaker?

For six outlets on a 30 amp breaker, you should use at least a 10-gauge wire to handle the load. This wire size is recommended to ensure proper flow of electricity without overheating. Always consult local electrical codes and regulations to ensure compliance with safety standards.


What gauge romex for outlets?

For general residential outlets, 12-gauge Romex is commonly used. This wire size is capable of handling the typical load requirements of outlets in homes. Make sure to consult your local electrical code to confirm the appropriate wire gauge for your specific installation.


Can 15 amp rated outlets be used with twelve gauge wire?

A. It's 240 volts & B. Wire size is a function of amperage. 12-gauge wire is used with 20 amperes or less. So, 12-gauge wire can be used with 120V/20A or 240V/20A. Keep in mind though that 240V in the U.S. has 2 live 120V lines so if you encounter a white wire, it's probably an unmarked live & should be repainted as black or better yet, red (to indicate the 2nd live wire).


What wire size is required for a branch circuit with 10 outlets and a 15 amp breaker?

With a 15 A breaker you need 14 Gauge wire. Normally you would only put 8 outlets on a 15 A circuit. If you have the option you shoudl consider a 20 A circuit, use 20A receptacles and 12 gauge wire. Comment: The question was on a homeowners electrical exam. My answer was also 14 gauge however, the tester said the answer was 12 ga. I thought maybe there was something special about the 10 outlets. For example, 10x180 VA per outlet/120V = 15 A which is right at the limit for 14 ga but would be 75% for the 12 ga wire.


What are the standard Romex wire colors used in electrical wiring?

The standard Romex wire colors used in electrical wiring are black, white, and bare copper.


What size wire should be used to connect a water heater from the panel?

The wire size is dependent upon the wattage size of your water heater. The higher the wattage the larger the wire size. A standard 3000 watt heater will use a two pole 20 amp breaker connected to 2C #12 wire.


Why is wire sized in sq mm?

It is metric that is used in the European standard of wire measurement.