Best Answer

A #6 copper conductor is rated at 65 amps. To connect to a 50 amp RV outlet you will need a four conductor #6 SOW 600 volt cabtire. The black and red wires go on terminals X and Y. The white wire goes on terminal W. The green wire goes on terminal G.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is standard size wire used for 50 amp RV outlets?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

What is the minimum wire size used in a commercial building?

The minimum size wire that engineers spec for industrial and commercial installations is #12 and it usually is stranded not solid wire.


How many wall outlets can you have in a circuit using a A breaker?

Assuming this is not an office of a place where lots of the outlets will be used to power items that draw lots of current on a 15 amp circuit wired with 14/2 wire I would limit it to no more than 10 outlets and lights combined. On a 20 amp circuit wired with 12/2 wire I would limit it to a 14 outlets and lights combined. There is no limit in the code. You just use common sense based on what is going to be used on this circuit.


What is the wire size for 208 volt?

As with any electrical installation, the wire size used depends on the expected maximum current the wire will carry. That cannot be determined by voltage alone.


Why is it necessary to upgrade old electrical outlets?

Older style wires and cables are not as safe as the current types used for house wiring. For example, older insulation becomes brittle with age and can break when the wire is moved. Newer wiring is a lot more flexible and can handle age much better than the old insulation. Newer wiring specifications require that all circuits include a connection to ground, older outlets do not have that requirement. Newer outlets are far safer, not just because of the ground wire but because of the plug polarity that has been introduced to the newer standard.


What gauge wire is used to run smoke detectors?

14-3 Is the standard wire use for residental smoke detectors.

Related questions

What is 12 awg?

12 AWG stands for American Wire Gauge 12, which is a standard measurement of the diameter of electrical wire. It indicates a wire with a diameter of 0.0808 inches and is commonly used for household electrical wiring, outlets, and switches.


Can 14-2 wire be used for outlets?

Yes, 14-2 wire can be used for outlets in residential settings. The 14-2 wire consists of a black (hot), white (neutral), and bare copper (ground) conductor. It is suitable for circuits with a 15-amp breaker and can safely power standard outlets.


What size of wire use if you have 6 outlet with 30 amp breaker?

For six outlets on a 30 amp breaker, you should use at least a 10-gauge wire to handle the load. This wire size is recommended to ensure proper flow of electricity without overheating. Always consult local electrical codes and regulations to ensure compliance with safety standards.


Can 15 amp rated outlets be used with twelve gauge wire?

No, 15 amp rated outlets should be used with 14 gauge wire. For 12 gauge wire, you should use outlets rated for a higher amperage, such as 20 amps, to match the capacity of the wire and reduce the risk of overheating. It's important to match the wire gauge with the appropriate outlet rating to ensure safety and proper functionality.


What wire size is required for a branch circuit with 10 outlets and a 15 amp breaker?

With a 15 A breaker you need 14 Gauge wire. Normally you would only put 8 outlets on a 15 A circuit. If you have the option you shoudl consider a 20 A circuit, use 20A receptacles and 12 gauge wire. Comment: The question was on a homeowners electrical exam. My answer was also 14 gauge however, the tester said the answer was 12 ga. I thought maybe there was something special about the 10 outlets. For example, 10x180 VA per outlet/120V = 15 A which is right at the limit for 14 ga but would be 75% for the 12 ga wire.


What size wire should be used to connect a water heater from the panel?

A 10-gauge wire is typically used for a 30-amp circuit required for a water heater. However, it's essential to consult the manufacturer's instructions or an electrician for the specific wire size needed based on the water heater's specifications and local electrical codes.


Why is wire sized in sq mm?

It is metric that is used in the European standard of wire measurement.


How do you wire outlets parallel?

The same way


What size wire is used for a 220 volt dryer?

For a standard clothes dryer, new homes are roughed in with 3C #10 cable which is rated at 30 amps.


What is wire standard 60hz 220v ac cable?

The wire standard for a 60Hz 220V AC cable typically refers to a wire size of at least 10 AWG for standard household wiring. This type of cable is commonly used for powering household appliances and electronics. It is important to ensure that the wire size is appropriate for the electrical load to avoid overheating and potential hazards.


What size of wire should be used for 60Hz?

The frequency has no direct relationship to the size of wire. Wire is sized as to the amount of current a load draws in a circuit.


Is American Wire Gauge a standard used to describe the size of a wire?

Yes, American Wire Gauge (AWG) is a system commonly used in North America to denote the diameter of electrical wiring. It assigns a specific number to different wire sizes, with smaller numbers representing thicker wires.