3/0 copper wire with 90 degree insulation is rated at 210 amps. 75 degree insulation is rated at 200 amps.

User Avatar

Wiki User

16y ago

What else can I help you with?

Continue Learning about Electrical Engineering

What is the minimum size neutral for three sets of parallel 500kcm copper conductors for a service?

On large service entrance services the neutral can be reduced. The amperage of the service and the voltage of the service and the insulation factor of the 500 MCM conductors need to be stated to answer this question correctly.


What size ground wire needed for a 200amp service panel in new jersey?

#6 bare copper wire.


What is the correct pipe size for a service entrance to a house?

The correct pipe size for a service entrance to a house typically depends on the electrical load and local building codes. For residential service, a common size is 1 inch for a 100-amp service and 1.25 inches for a 200-amp service. It's essential to consult the National Electrical Code (NEC) and local regulations to ensure compliance and proper sizing based on the specific requirements of the installation. Always consider factors like distance from the service panel and the type of conductors used.


What size conductors are needed to run a 400 foot residential underground electric service?

Need to know what size service is going to be installed at the end of the run.


What wire size is needed to ground a 300 amp service panel in USA?

Notes: 1. Where multiple sets of service-entrance conductors are used as permitted in Section 230-40, Exception No. 2, the equivalent size of the largest service-entrance conductor shall be determined by the largest sum of the areas of the corresponding conductors of each set. 2. Where there are no service-entrance conductors, the grounding electrode conductor size shall be determined by the equivalent size of the largest service-entrance conductor required for the load to be served. 1 This table also applies to the derived conductors of separately derived ac systems. 2 See installation restrictions in Section 250-64(a).

Related Questions

What is the minimum size neutral for three sets of parallel 500kcm copper conductors for a service?

On large service entrance services the neutral can be reduced. The amperage of the service and the voltage of the service and the insulation factor of the 500 MCM conductors need to be stated to answer this question correctly.


What size ground wire is needed for 200amp service pannel in Chicago?

200 amp service in chicago uses 3 aught.


What size service conductors for a 225 amp 3 phase service?

For a 225 amp 3-phase service, typically you would use 3 sets of 3/0 AWG copper conductors or 250 kcmil aluminum conductors for the service entrance conductors. Make sure to consult the National Electrical Code (NEC) and local regulations for specific requirements.


What size copper main bonding jumper is required based on the service entrance conductors being rated at 250 kcmil thwn-thnn copper?

A size 3/0 AWG copper main bonding jumper is typically required for service entrance conductors rated at 250 kcmil copper. This is based on NEC requirements for sizing the main bonding jumper to be at least 1/10th the circular mil area of the largest service entrance conductor.


What size ground wire needed for a 200amp service panel in new jersey?

#6 bare copper wire.


What is the correct pipe size for a service entrance to a house?

The correct pipe size for a service entrance to a house typically depends on the electrical load and local building codes. For residential service, a common size is 1 inch for a 100-amp service and 1.25 inches for a 200-amp service. It's essential to consult the National Electrical Code (NEC) and local regulations to ensure compliance and proper sizing based on the specific requirements of the installation. Always consider factors like distance from the service panel and the type of conductors used.


What is the recommended size for a 100 amp service entrance cable?

The recommended size for a 100 amp service entrance cable is typically 2 AWG copper or 1/0 AWG aluminum.


What is the minimum size of service entrance conductor?

The wire that is used for connecting the ground rod or plate to the electrical distribution is governed by the size of the electriclal distribution. In Canada a #6 bare copper is the minimum size for a 200 amp service.


What size service ground is needed for a 350 parallel service?

From the question it is hard to establish whether the service size is 350 amps or the service conductors are 350 MCM in parallel. If the service is 350 amps, the grounding conductor is #3 bare copper wire. Parallel 350 MCM conductors will allow for a 600 amp service. The grounding conductor for a 600 amp service is a #1 bare copper wire.


What size service conductors do you need for a single phase 600 amp commercial panel?

The size of wire for service entrance conductors for a 400 amp 3 phase service could be 500 MCM copper. This is very large size wire and difficult to bend and shape, to connect to terminals in the main disconnect and distribution panel. This problem is solved by using parallel conductors or on higher ampacities triple conductors. Using parallel conductors the wire size would be three ought (3/0) copper.


What size conductors are needed to run a 400 foot residential underground electric service?

Need to know what size service is going to be installed at the end of the run.


What is the recommended cable size for a 200 amp service entrance cable?

The recommended cable size for a 200 amp service entrance is typically 2/0 AWG copper or 4/0 AWG aluminum.