Wiki User
∙ 11y agoHave a look at this image https://encrypted-tbn2.Google.com/images?q=tbn:ANd9GcRUaQ6taOcwPgdxxCUE-XfDoy3vIl4Oe1dCCgyJt1B37v673qLo3w . I am sure it will help you understand that.
Wiki User
∙ 11y agobecause of their magnetic field lines
Yes opposite sides are parallel and congruent
just draw lines opposite of each other but not connected. and just make the ray the opposite direction of the other and you have it done.
Yes. The opposite sides of a square are equal and parallel.
A Trapezium (can have two opposite sides parallel)A kite has no parallel opposite sides
because of their magnetic field lines
Field strength between two conductor increase and attracts each other
parallel paths are conductors where current direction is same
parallel
Forces which are parallel and acting in same direction are called like parallel forces. Forces which are parallel and acting in opposite direction are called unlike parallel forces.
Forces which are parallel and acting in same direction are called like parallel forces. Forces which are parallel and acting in opposite direction are called unlike parallel forces.
The required size of the service grounding conductor for a 350 amp parallel service will depend on the specific installation requirements and local codes. It is recommended to consult with a licensed electrician or engineer to determine the proper size based on factors such as the type of wiring used, the distance between the service entrance and the transformer, and the local ground conditions.
In transmission line minimum 3 conductors are run in parallel. Every conductor has a flux which produce losses in other conductor which is run with parallel. So in the middle one conductor the losses is double in respect to other two conductors. At the end of the line the voltage of the middle one conductor is reduced from other conductors due to these losses. The transposition tower is used to change the conductors. By using these tower we shift each conductor position. So we use these towers in long transmission line so that these losses becomes equal for each conductor. and voltage will be almost equal at the end of the transmission line. Regards. Vishal kr. Sharma. (Simplex infrastructures ltd, Power Transmission & Distribution division)
For an 800 amp service with parallel sets of 500 kcmil copper conductors, the grounding electrode conductor size should be based on the largest conductor in the parallel set. The grounding electrode conductor size should be sized based on Table 250.66 in the NEC, which recommends a minimum size of 3/0 AWG copper for 1/0 AWG or larger service-entrance conductors.
Like Parallel forces are the forces that are parallel to each other and have same direction. Unlike parallel forces are the forces that are parallel but have directions opposite to each other.
The direction of kinetic friction is always opposite to the direction of motion of the object.
Frictional force always acts opposite to the direction of motion or the impending motion of an object, parallel to the surface in contact.