Best Answer

NO! The circuit is being overloaded. Danger of fire will result from just changing the size of the fuse or breaker.

A 30 amp breaker may be used with #10 wiring. #10 is rated for 30 amps. I would be hesitant to do this if the tripping problem is something new though.

User Avatar

Wiki User

โˆ™ 9y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

โˆ™ 8mo ago

No, it is not recommended. A 20 amp breaker should be used with a wire gauge of 12 or smaller to ensure the wire does not overheat and cause a fire hazard. Using a 10 gauge wire on a 20 amp breaker could potentially overload the wire and overheated it.

This answer is:
User Avatar

User Avatar

Wiki User

โˆ™ 14y ago

Yes.

Additional InformationBut why would you want to?

Use 10 AWG wire for 30 Amp circuits, 12 AWG wire for 20 Amps and 14 AWG for 15 Amps.

You're wasting copper if you use over-sized wire.

This answer is:
User Avatar

User Avatar

Wiki User

โˆ™ 9y ago

Yes, the breaker can be changed. The breaker is sized to protect the wire that is connected to it. A #10 conductor is rated at 30 amps. Any load draws what it needs to operate. It is oblivious that if the 20 amp circuit breaker is tripping then the breaker is too small for the connected load. That is probably why the #10 conductor was used in the first place. It happens quite often that if the correct breaker size is not available then a substitute is put in its place. In this case a 20 was used instead of the correct 30 amp breaker.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can 10 gauge wire be used on a 20 amp breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What gauge wire should be used for a 30 amp breaker?

For a 30 amp breaker, a 10-gauge wire should be used.


What gauge wire should be used for a 60 amp breaker?

For a 60 amp breaker, a 6-gauge wire should be used.


What gauge wire should be used for a 50 amp breaker?

For a 50 amp breaker, a 6-gauge wire should be used to ensure safe and proper electrical connection.


What wire gauge should be used for a 60 amp breaker?

For a 60 amp breaker, a wire gauge of at least 6 AWG should be used to ensure proper electrical safety and performance.


Is it safe to use 10 gauge wire on a 20 amp breaker for a microwave?

No, 10 gauge wire requires the use of a 30 amp breaker. A 20 amp breaker is only used on 12 gauge wire.


What gauge wire is used on a 20 amp breaker?

AWG 12.


What size breaker should be used on a 20 amp motor?

30 amp breaker with #10 gauge copper wire


What size wire should be used for a 25 amp breaker?

For a 25 amp breaker, a wire size of at least 10 gauge should be used to safely handle the current.


What gauge wire used for a fifteen amp breaker?

AWG # 14 copper.


What is the recommended wire size for a 20 amp breaker?

The recommended wire size for a 20 amp breaker is typically 12-gauge wire.


What size wire should be used for a 100 amp breaker?

For a 100 amp breaker, a wire size of 2 AWG (American Wire Gauge) should be used to ensure proper electrical safety and performance.


Can 13 gauge wire be connected to a 20 amp breaker?

No, it is not recommended to connect 13 gauge wire to a 20 amp breaker. The wire gauge should match the amp rating of the breaker to prevent overheating and potential fire hazards. In this case, a 20 amp breaker should be used with at least 12 gauge wire.