Bonding of the neutral or grounded conductor to the earth ground or grounding conductor means that they are mechanically and electrically connected. That is, they have full continuity between each other. In most residential panels, the neutral bar, (where you screw down all of the neutral (white) wires) and the ground bar where you screw down all of the bare copper ground wires are on opposite sides of the panel. They are typically connected mechanically and electrically or bonded with a "crossover" bar which bolts in connecting the two bars. Bonding the neutral and ground is required by the NEC (National Electrical Code) on all panels which have a main disconnect. For example, if you have a typical 200 amp residential panel and it has a main 200 amp breaker or "main disconnect", then the neutral and grounds are to be bonded. If you have a main disconnect panel and the neutral and ground are not bonded, then you should bond them by running an insulated wire between them to connect them. That wire needs to be no less in size than the size of the incoming supply neutral wire in the panel. If you are at all confused, post again and be very specific about your question and someone may be able to answer you.

User Avatar

Wiki User

15y ago

What else can I help you with?

Continue Learning about Natural Sciences

Where are neutral and ground wires usually bonded together?

Neutral and ground wires are usually bonded together at the main service panel of a building, but should never be bonded together at any subpanel or other point downstream. This connection is made to provide a safe path for stray electrical current in case of a fault, and to ensure proper grounding and equipment safety.


Why do some electric panel have ground and neutral bonded together?

Some electric panels have the ground and neutral bonded together for safety reasons. This bonding can help prevent dangerous voltage levels and reduce the risk of electrical shocks in case of a fault. However, it is important to check local electrical codes and guidelines before making any modifications to ensure compliance and safety.


Downstream of the electrical service box the neatral and gound wire should be separted?

Yes, it is important to keep the neutral and ground wires separated downstream of the electrical service box. Mixing these two wires can create potential safety hazards, such as electrical shocks or fires. It is crucial to follow proper wiring practices and guidelines to ensure a safe electrical installation.


Are the neutral and ground bonded in a sub-panel of an out building?

No, in a sub-panel of an outbuilding, the neutral and ground should be kept separate and not bonded together. This is to prevent the potential for ground loops and to ensure proper functioning of the grounding system.


How can you tell if the ground wire is approriately bonded to the neutral and the cabinet at the service box?

Ground wire can be appropriately bonded to the neutral and cabinet at the service box by connecting the neutral and ground wires from the feeder wires to the neutral bus bar and the ground terminal located on the same cabinet at the service box. White wire (neutral) must be connected to bus bar and bare wire must be connected to ground terminal in the same cabinet.

Related Questions

Where are neutral and ground wires usually bonded together?

Neutral and ground wires are usually bonded together at the main service panel of a building, but should never be bonded together at any subpanel or other point downstream. This connection is made to provide a safe path for stray electrical current in case of a fault, and to ensure proper grounding and equipment safety.


The what of an electrical plug connects the metal to the ground?

The rounded third prong goes to earth ground at the main panel where the neutral is also bonded to ground.


How does a bonded neutral generator ensure safe and reliable electrical power distribution?

A bonded neutral generator ensures safe and reliable electrical power distribution by connecting the neutral and ground wires together at the generator. This helps to prevent electrical shocks and ensures proper grounding, reducing the risk of electrical hazards and ensuring a stable flow of electricity.


Why do some electric panel have ground and neutral bonded together?

Some electric panels have the ground and neutral bonded together for safety reasons. This bonding can help prevent dangerous voltage levels and reduce the risk of electrical shocks in case of a fault. However, it is important to check local electrical codes and guidelines before making any modifications to ensure compliance and safety.


Downstream of the electrical service box the neatral and gound wire should be separted?

Yes, it is important to keep the neutral and ground wires separated downstream of the electrical service box. Mixing these two wires can create potential safety hazards, such as electrical shocks or fires. It is crucial to follow proper wiring practices and guidelines to ensure a safe electrical installation.


Are the neutral and ground bonded in a sub-panel of an out building?

No, in a sub-panel of an outbuilding, the neutral and ground should be kept separate and not bonded together. This is to prevent the potential for ground loops and to ensure proper functioning of the grounding system.


What besides the neutral system should be bonded to the ground?

Answer for USA, Canada and countries running a 60 Hertz supply service.Nothing but the neutral bus should be bonded to the ground electrode.


Why shouldn't you ground electrical wiring?

Grounding is an important part of all electrical wiring like your home. Without proper grounding you are asking for all sorts of strange problems and safety issues. The power company provides electricity to your main panel and a good ground is required. This is usually a metal rod in the ground near your meter. This ground is bonded to the main electric panel. The neutral wire is in turn bonded to ground at the main panel. If you have a bad ground, neutral can float above ground causing shock hazards. I once had to chase down a shock problem in a shower. It turned out to be a case where the neutral and ground were not bonded at the main panel. What you shouldn't do is the hot side of power to ground.


How can the flow of electrons in an electrical circuit change without the neutral becoming hot ex. AC Power?

The neutral conductor is bonded to ground, and is therefore always at earth potential, which is the zero-reference for voltage.


What is the significance of the neutral to ground voltage in electrical systems?

The neutral to ground voltage in electrical systems is important because it helps to ensure the safety of the system. When the neutral to ground voltage is at the correct level, it means that there is a proper connection between the neutral and ground wires, which helps to prevent electrical shocks and fires. Monitoring and maintaining the neutral to ground voltage is crucial for the overall safety and functionality of an electrical system.


How can you tell if the ground wire is approriately bonded to the neutral and the cabinet at the service box?

Ground wire can be appropriately bonded to the neutral and cabinet at the service box by connecting the neutral and ground wires from the feeder wires to the neutral bus bar and the ground terminal located on the same cabinet at the service box. White wire (neutral) must be connected to bus bar and bare wire must be connected to ground terminal in the same cabinet.


What happens if you connect neutral to ground in an electrical circuit?

Connecting neutral to ground in an electrical circuit can create a dangerous situation called a ground fault. This can lead to electrical shock, fires, and damage to appliances or equipment. It is important to keep neutral and ground separate to ensure the safety and proper functioning of the electrical system.