answersLogoWhite

0


Best Answer

Bonding of the neutral or grounded conductor to the earth ground or grounding conductor means that they are mechanically and electrically connected. That is, they have full continuity between each other. In most residential panels, the neutral bar, (where you screw down all of the neutral (white) wires) and the ground bar where you screw down all of the bare copper ground wires are on opposite sides of the panel. They are typically connected mechanically and electrically or bonded with a "crossover" bar which bolts in connecting the two bars. Bonding the neutral and ground is required by the NEC (National Electrical Code) on all panels which have a main disconnect. For example, if you have a typical 200 amp residential panel and it has a main 200 amp breaker or "main disconnect", then the neutral and grounds are to be bonded. If you have a main disconnect panel and the neutral and ground are not bonded, then you should bond them by running an insulated wire between them to connect them. That wire needs to be no less in size than the size of the incoming supply neutral wire in the panel. If you are at all confused, post again and be very specific about your question and someone may be able to answer you.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

6mo ago

No, neutral and ground wires should not be bonded downstream of an electrical box. Proper bonding should only occur at the main electrical panel to prevent the creation of ground loops and ensure electrical safety. It is important to follow electrical codes and guidelines to maintain a safe electrical system.

This answer is:
User Avatar

User Avatar

Wiki User

13y ago

Yes, its a good idea to ground sensitive equipment at the surge protector. You can do this with an adapter that isolates house ground from the ground wire you are going to run from a water pipe im guessing, if you are still not sure you want to combine them. Shorting the path and and using heavy copper wire to ground from any protection devise improves its ability to protect your equipment and improves its reaction time to a spike. It is also a must to add an additional ground to both your washing machine and dryer to the chassis and to all your 220 devises that utilize high current capable wiring, this will insure that your breaker will trip if there is a short in the devise otherwise there is a possibility of a fatal shock. Run individual ground wires for each devise also. It is a good idea to have a professional to install all electrical connections.

This answer is:
User Avatar

User Avatar

Wiki User

13y ago

In Brazil, a neutral wire has green and white stripes.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can neutral and ground wires be bonded downstream of electrical box?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Where are neutral and ground wires usually bonded together?

Neutral and ground wires are usually bonded together at the main service panel of a building, but should never be bonded together at any subpanel or other point downstream. This connection is made to provide a safe path for stray electrical current in case of a fault, and to ensure proper grounding and equipment safety.


Why do some electric panel have ground and neutral bonded together?

Some electric panels have the ground and neutral bonded together for safety reasons. This bonding can help prevent dangerous voltage levels and reduce the risk of electrical shocks in case of a fault. However, it is important to check local electrical codes and guidelines before making any modifications to ensure compliance and safety.


Downstream of the electrical service box the neatral and gound wire should be separted?

Yes, it is important to keep the neutral and ground wires separated downstream of the electrical service box. Mixing these two wires can create potential safety hazards, such as electrical shocks or fires. It is crucial to follow proper wiring practices and guidelines to ensure a safe electrical installation.


Are the neutral and ground bonded in a sub-panel of an out building?

No, in a sub-panel of an outbuilding, the neutral and ground should be kept separate and not bonded together. This is to prevent the potential for ground loops and to ensure proper functioning of the grounding system.


How can you tell if the ground wire is approriately bonded to the neutral and the cabinet at the service box?

To check if the ground wire is properly bonded to the neutral and the cabinet at the service box, you can use a multimeter to test for continuity between the ground wire, the neutral wire, and the metal cabinet of the service box. If there is continuity between all three, then the bonding is appropriate. It is important to ensure that this bonding is done correctly to provide a safe electrical system.

Related questions

Where are neutral and ground wires usually bonded together?

Neutral and ground wires are usually bonded together at the main service panel of a building, but should never be bonded together at any subpanel or other point downstream. This connection is made to provide a safe path for stray electrical current in case of a fault, and to ensure proper grounding and equipment safety.


The what of an electrical plug connects the metal to the ground?

The rounded third prong goes to earth ground at the main panel where the neutral is also bonded to ground.


Why do some electric panel have ground and neutral bonded together?

Some electric panels have the ground and neutral bonded together for safety reasons. This bonding can help prevent dangerous voltage levels and reduce the risk of electrical shocks in case of a fault. However, it is important to check local electrical codes and guidelines before making any modifications to ensure compliance and safety.


Downstream of the electrical service box the neatral and gound wire should be separted?

Yes, it is important to keep the neutral and ground wires separated downstream of the electrical service box. Mixing these two wires can create potential safety hazards, such as electrical shocks or fires. It is crucial to follow proper wiring practices and guidelines to ensure a safe electrical installation.


Why shouldn't you ground electrical wiring?

Grounding is an important part of all electrical wiring like your home. Without proper grounding you are asking for all sorts of strange problems and safety issues. The power company provides electricity to your main panel and a good ground is required. This is usually a metal rod in the ground near your meter. This ground is bonded to the main electric panel. The neutral wire is in turn bonded to ground at the main panel. If you have a bad ground, neutral can float above ground causing shock hazards. I once had to chase down a shock problem in a shower. It turned out to be a case where the neutral and ground were not bonded at the main panel. What you shouldn't do is the hot side of power to ground.


Are the neutral and ground bonded in a sub-panel of an out building?

No, in a sub-panel of an outbuilding, the neutral and ground should be kept separate and not bonded together. This is to prevent the potential for ground loops and to ensure proper functioning of the grounding system.


What besides the neutral system should be bonded to the ground?

Answer for USA, Canada and countries running a 60 Hertz supply service.Nothing but the neutral bus should be bonded to the ground electrode.


How can the flow of electrons in an electrical circuit change without the neutral becoming hot ex. AC Power?

The neutral conductor is bonded to ground, and is therefore always at earth potential, which is the zero-reference for voltage.


How can you tell if the ground wire is approriately bonded to the neutral and the cabinet at the service box?

To check if the ground wire is properly bonded to the neutral and the cabinet at the service box, you can use a multimeter to test for continuity between the ground wire, the neutral wire, and the metal cabinet of the service box. If there is continuity between all three, then the bonding is appropriate. It is important to ensure that this bonding is done correctly to provide a safe electrical system.


Is it OK illegal or dangerous to connect the neutral to ground to make the circuit work?

Connecting the neutral and ground wires in a circuit is dangerous and against electrical code because it can create a hazardous condition known as a ground fault. This can lead to electric shock, fires, and damage to equipment. It is important to keep the neutral and ground wires separate to ensure the safety and integrity of the electrical system.


What besides neutral system should be bonded to ground?

In addition to the neutral conductor, metal enclosures, metal conduit, metal raceways, and equipment grounds (green or bare wires) should be bonded to ground in an electrical system for safety. This helps provide a path for fault currents to flow safely to the ground, reducing the risk of electric shock or fire hazards.


What happens if you splice ground wire and neutral wire in a high hat fixture?

Splicing the ground wire and neutral wire together in a high hat fixture is unsafe and can create a dangerous electrical situation. The ground wire is meant for safety and should never be connected to the neutral wire, as it can lead to electric shock hazards and disrupt the proper functioning of the electrical system. It is important to always follow proper wiring practices and consult a qualified electrician for any electrical work.