answersLogoWhite

0


Best Answer

No, it would not be safe because 250v is too high for that breaker.

<<>>

In North America all household breakers are rated at 120/240 volts. A 250 volt 15 amp breaker would would be a two pole breaker and take up two slots in the distribution panel. This can be pulled out and replaced with two separate 15 amp breakers or one 15 amp breaker and a slot panel filler to cover the second slot.

User Avatar

Wiki User

βˆ™ 10y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

βˆ™ 2w ago

No, you cannot interchange a 250v 15 amp breaker with a 115v 15 amp breaker. Breakers are voltage-specific devices, and using the wrong voltage breaker can be a safety hazard and can damage your electrical system. It is essential to use the correct voltage and amperage ratings for your electrical circuit.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can you change a 250v 15 amp breaker with a 115v15 amp breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can you change a 50 amp receptacle to a 15 amp receptacle?

Yes as long as you change the 50 amp breaker to a 15 amp breaker. You will be hard pressed to get the 50 amp #6 wire under the terminals of the 15 amp receptacle.


Can you plug a 15a 250v ac into a 30a 250v plug?

No, the amperage pin configurations are different between a 15 amp and a 30 amp plug.


Can you properly switch prongs on a 20 amp 250v twist lock to change it to a 125v?

No, it is against the National Electrical Code to wire a receptacle with the wrong voltage. You should call a qualified electrician to change the 250V receptacle to a 125V receptacle.


Can you upgrade a 15 Amps circuit breaker for a 40 Amp for a 8.5 Watt shower?

Not unless you change the wiring for that circuit. The breaker protects the wiring and if you install a 40 amp breaker on a 15 amp wire circuit you will have a fire in your home.


How do you calculate ampere given 250v AC 60W?

Divide the watts by the voltage to get current (amps). 60W / 250V = about 1/4 Amp.


Duplex receptacle circuit given 15 amp breaker 225 amp load?

A 15 amp breaker is not sufficient for a 225 amp load. You would need a breaker that matches the load current, such as a 225 amp breaker. Using a 15 amp breaker for a 225 amp load would cause the breaker to trip immediately due to overcurrent.


How do you turn a 30 amp circuit into a 15 amp cicuit?

Replace the 30 Amp Breaker with a 15 Amp breaker.


Can you use a 60 amp breaker with a 50 amp overcurrent device?

A 50 amp breaker is an overcurent device.


Is a double throw 15amp breaker the same as a 30 amp breaker amp?

You have a double pole breaker for 240Volt supply. The maximum current is 15 amp.


Can a 4 amp breaker be used to replace a 35 amp breaker for ac unit?

NO!


Is the 30 amp breaker for a motorhome the same as for a house?

Yes, a 30 amp breaker is a 30 amp breaker. It must however be able to fit the box it is installed in.


Should 25 amps breaker be replaced by 20 amps?

For typical residential house wiring 12 AWG wire is required for a 20 Amp breaker. If you change out the breaker for a 25 A breaker you would have to rewire the circuit with 10 AWG. In that case you could up the breaker to 30 Amps. All outlets and switches should be rated at the same voltage and current as the breaker.