answersLogoWhite

0

If by "60 amp box" you mean a 60-amp service panel (circuit breakers or fuses), you would generally get a 60-A panel that has several slots designed to accept a variety of compatible breakers, from 15A to 60A.

If you have a "box" with no breakers, you would need another "subpanel", with wires from the 60A box to the new subpanel, and install one or more 15A breakers in the subpanel. If you don't need more than one breaker, you might also simply use a 15A disconnect panel with a single breaker in it.

User Avatar

Wiki User

12y ago

What else can I help you with?

Related Questions

How do you turn a 30 amp circuit into a 15 amp cicuit?

Replace the 30 Amp Breaker with a 15 Amp breaker.


Duplex receptacle circuit given 15 amp breaker 225 amp load?

A 15 amp breaker is not sufficient for a 225 amp load. You would need a breaker that matches the load current, such as a 225 amp breaker. Using a 15 amp breaker for a 225 amp load would cause the breaker to trip immediately due to overcurrent.


How do you replace a 15 amp breaker in the circuit box?

To replace a 15 amp breaker, first shut off the main power to the circuit box. Then, remove the cover of the circuit box and unscrew the old breaker. Disconnect the wires attached to the old breaker, connect them to the new 15 amp breaker, and securely screw it in place. Finally, turn the main power back on to restore electricity.


Can you hook a 15 amp and 20 amp breaker to a breaker box using 20 amp wire?

No, you should use wire that matches the lowest amp rating of the breakers connected to it. In this case, you should use 15 amp wire since one of the breakers is a 15 amp breaker. Matching the wire gauge to the lowest amp rating ensures the wire is protected from overheating in case of a short circuit.


Can I replace a 15 amp breaker with a 20 amp breaker?

No, you should not replace a 15 amp breaker with a 20 amp breaker without consulting a licensed electrician. The breaker size should match the wire size to prevent overheating and potential fire hazards.


How many volts can you draw off of a 15amp breaker?

It's the amps that are controlled by the breaker not the volts. You can have a 600 volt 15 amp breaker, you can have a 347 volt 15 amp breaker. The breaker will trip when you exceed 15 AMPS.


What is the maximum current rating for a 15 amp circuit breaker?

The maximum current rating for a 15 amp circuit breaker is 15 amps.


Can you change a 50 amp receptacle to a 15 amp receptacle?

Yes as long as you change the 50 amp breaker to a 15 amp breaker. You will be hard pressed to get the 50 amp #6 wire under the terminals of the 15 amp receptacle.


Is it safe to use a 15 amp outlet on a 20 amp breaker?

No, it is not safe to use a 15 amp outlet on a 20 amp breaker as it can lead to overheating and potential fire hazards. It is important to match the outlet's amp rating with the breaker's amp rating for safety.


Is it safe to install a 15 amp outlet on a 20 amp breaker?

No, it is not safe to install a 15 amp outlet on a 20 amp breaker. The outlet should match the amperage of the breaker to prevent overheating and potential fire hazards.


Is a double throw 15amp breaker the same as a 30 amp breaker amp?

You have a double pole breaker for 240Volt supply. The maximum current is 15 amp.


Can you replace a 15 amp breaker with a 20 amp breaker safely?

No, it is not safe to replace a 15 amp breaker with a 20 amp breaker without ensuring that the wiring and electrical components can handle the increased current. This could lead to overheating and potentially cause a fire hazard.