At least 000 AWG copper or better yet, 0000 AWG copper. Another consideration is how far the 200 Amps are to be carried. Wire has resistance and 0000 copper has a resistance of .04901 Ohms per thousand feet. At 200 Amps, this means that over one thousand feet the voltage will be 9.8 Volts lower than at the starting point.
Chat with our AI personalities
For a residential 200 amp service, it is recommended to use 3/0 copper or 250 MCM aluminum wire for the service entrance. Make sure to consult with a licensed electrician to ensure that the wire size meets local building codes and regulations.
The size of the ground wire for a circuit is typically based on the size of the circuit breaker protecting that circuit. For a 200 amp circuit breaker, the recommended ground wire size is 4/0 AWG (American Wire Gauge) copper wire. This wire size helps ensure that the ground wire can safely carry any fault currents that may occur in the electrical system.
For a 200 amp service, it is recommended to use 3/0 copper or 4/0 aluminum wire. These wire sizes are suitable for handling the electrical load of a 200 amp service with the appropriate safety margin. It is important to consult with a qualified electrician and adhere to local electrical codes when determining the wire size for a 200 amp service.
For a 125 amp sub panel located less than 200 feet away from a 200 amp panel, you would typically use a 2 AWG copper wire or 1/0 AWG aluminum wire to safely carry the current load. It's important to follow local electrical codes and regulations when selecting the wire size.
Yes, but at every reduction in wire size there has to be a breaker sized to the smaller wire size. The wire size for 100 amp panels is recommended at #3 copper conductor. From the 200 amp feeder panel you will require a 100 amp two pole breaker for each of the two 100 amp services. Keep in mind that if you run the 100 amp services close to maximum this will take away the capacity of the 200 amp service for other branch circuits coming off of it. Also keep in mind that if the panels are located, not in the same building as the 200 amp service that the 100 amp panels will be treated as separate services and will have to be constructed like a 100 amp service. This includes ground rods. Also the bonding screw will have to be removed that connects the neutral buss to the panel enclosure.
Yes, in a residential 200 amp panel, the neutral wire is typically the same size as the hot wires. This is to ensure that the neutral wire can safely carry the same current as the hot wires and maintain proper balance in the electrical system. Always consult the National Electrical Code or a qualified electrician for specific requirements.