answersLogoWhite

0

AWG 2/0 hots with a 1/0 awg neutral with a bare 6 grnd or a 3/0 awg comerrcial

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Natural Sciences

Can you tap off of a 200 amp service for 2 100 amp panels?

Yes, but at every reduction in wire size there has to be a breaker sized to the smaller wire size. The wire size for 100 amp panels is recommended at #3 copper conductor. From the 200 amp feeder panel you will require a 100 amp two pole breaker for each of the two 100 amp services. Keep in mind that if you run the 100 amp services close to maximum this will take away the capacity of the 200 amp service for other branch circuits coming off of it. Also keep in mind that if the panels are located, not in the same building as the 200 amp service that the 100 amp panels will be treated as separate services and will have to be constructed like a 100 amp service. This includes ground rods. Also the bonding screw will have to be removed that connects the neutral buss to the panel enclosure.


What size wire should i use for 200 amp service?

For a 200 amp service, it is recommended to use at least a 3/0 copper or 4/0 aluminum wire. These wire sizes can safely handle the current and provide necessary voltage drop considerations for a 200 amp service.


Ground wire size for 200?

The size of the ground wire for a circuit is typically based on the size of the circuit breaker protecting that circuit. For a 200 amp circuit breaker, the recommended ground wire size is 4/0 AWG (American Wire Gauge) copper wire. This wire size helps ensure that the ground wire can safely carry any fault currents that may occur in the electrical system.


Can you use one ought copper wire size for common lead to a 200 amp service panel?

No, a 1/0 copper wire size is not sufficient for a 200 amp service panel. For a 200 amp service panel, you would typically need to use 3/0 copper wire size for the service entrance cable. It is important to consult with a qualified electrician to ensure proper sizing and safety.


How do you know what wire is ground on 200 amp service?

In a 200 amp service panel, the ground wire is typically a bare copper wire or green insulated wire. It is connected to the ground bar within the panel. Make sure to consult the manufacturer's instructions or a licensed electrician for guidance specific to your installation.

Related Questions

What is the recommended aluminum wire size for a 200 amp service?

The recommended aluminum wire size for a 200 amp service is typically 2/0 AWG.


What size underground wire is recommended for a 200 amp service?

For a 200 amp service, it is recommended to use a size 2/0 or larger underground wire.


What is the recommended wire size for a 200 amp service using aluminum wire?

The recommended wire size for a 200 amp service using aluminum wire is typically 2/0 AWG (American Wire Gauge).


What information can I find in the 200 amp service wire size chart?

The 200 amp service wire size chart provides information on the recommended wire size to use for a 200 amp electrical service. This chart helps determine the appropriate wire gauge based on factors like the length of the wire run and the type of material being used.


What size aluminum wire should be used for a 200 amp service?

For a 200 amp service, a minimum of 2/0 gauge aluminum wire should be used.


What is the recommended type of wire for a 200 amp underground service?

For a 200 amp underground service, it is recommended to use copper wire with a minimum size of 2/0 AWG. Copper wire is preferred for its conductivity and durability, making it suitable for handling the high electrical load of a 200 amp service.


What size wire for 25 amp service with a 200 foot run?

10 guage


What type of wire, specifically aluminum wire, should be used for a 200 amp service?

For a 200 amp service, it is recommended to use aluminum wire that is at least 4/0 gauge in size to ensure proper conductivity and safety.


Do you need to change the wire size going from 100 amp service to 150 amp service?

Yes, the wire size has to be increased. The existing 100 amp service will now probably have a #3 conductor with an insulation factor of 75 or 90 degrees C which is rated for 100 and 105 amps respectively. Increasing to a 150 amp service will use a #1/0 wire size. If you are thinking of an upgrade, skip the 150 amp service and go to a 200 amp panel. New homes are installing 200 amp 42 circuit panels. The extra cost is only reflected in the materials as the labour costs will be the same regardless whether a 150 amp or a 200 amp panel is installed. The wire size for a 200 amp panel is #3/0. With an insulation factor of 75 or 90 degrees C the rating is 200 or 210 amps respectively.


What size neutral wire for 200 amp service panel?

AWG # 3/0 copper.


What size wire do I need for a 200 amp service?

For a 200 amp service, you will typically need a wire size of 2/0 AWG (American Wire Gauge) for copper or 4/0 AWG for aluminum. It is recommended to consult with a licensed electrician for specific requirements and installation guidelines.


What type of wire should be used for a 200 amp service installation?

For a 200 amp service installation, it is recommended to use copper wire with a gauge size of 2/0 or larger to ensure proper electrical conductivity and safety.