answersLogoWhite

0


Best Answer

AWG # 3/0 copper.

User Avatar

Wiki User

10y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What size neutral wire for 200 amp service panel?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How do you know what wire is ground on 200 amp service?

In a 200 amp service panel, the ground wire is typically a bare copper wire or green insulated wire. It is connected to the ground bar within the panel. Make sure to consult the manufacturer's instructions or a licensed electrician for guidance specific to your installation.


Is neutral wire same size as hot in 200 amp panel?

Yes, in a residential 200 amp panel, the neutral wire is typically the same size as the hot wires. This is to ensure that the neutral wire can safely carry the same current as the hot wires and maintain proper balance in the electrical system. Always consult the National Electrical Code or a qualified electrician for specific requirements.


Should neutral wire of lamp be connected to the 3amp or the 6 amp side of a canopy switch?

You should never switch the neutral wire. The neutral of the appliance should be connected directly to the neutral wire leading to the service panel neutral bar.


Why do white wire mark 120v?

Because the white wire on a 120 volt circuit is the neutral wire that is connected to the silver screw on outlets and switches. It is connected to the neutral bar in the service panel.


What wire size for 400 amp service neutral size?

You need to look at the regulations that apply in your country. If in doubt, use a neutral wire of the same size as the live wire or wires.


Is the neutral wire consider a hot wire?

Neutral is neither Hot nor ground. Neutral is the return wire for electrical service. It is a requirement , by law, that the Neutral Wire Feed into an electrical service box (main panel) be BONDED to the box and the Earth ground. Thie effectively makes the neutral in circuits out of the service panel equal to ground. But as it enters the service panel from the utility and meter pan, it is not ground. <<>> The only time that the neutral can have voltage on it is if it gets disconnected from the distribution point. Then the voltage that is supplied to the load will continue through the load and stop at the disconnection point. If you touch the uninsulated part of the neutral wire and touch any grounded equipment at the same time your body will act as a conductor for the load circuit. You will receive a nasty shock. This scenario is the only time that the neutral is "hot".


What is rod earthing?

It is the installation of ground rods at a service entrance distribution to bring the relative resistance to ground to be within 5 ohms of the utility's distribution network. This grounding system is then connected to the service distribution with a calculated size wire and connected to the distribution at a point within the distribution panel, where the service neutral wire joins the neutral bus bar.


What is the minimum service size for a 225amp residential service?

A 200 amp service panel with a 60 amp sub-panel.


How do you ground a 100 amp service panel?

In the service distribution panel there are termination points at the top of the panel. Two of the utilities "hot" conductors terminate on the main breaker. The neutral utility termination point is on a terminal block usually off to the side near the main hot terminations. It is in this neutral termination block where the system ground connects from the ground rods to the distribution panel. For a 100 amp panel the wire size will be a #6 bare copper conductor.


How do you wire a 15 amp 120V breaker in a 240v 30 amp breaker panel?

Look to see if the 30 amp panel is fed with a two wire or a three wire. If it is a two wire then you are out of luck. If the panel is fed with a three wire then the panel should have the neutral terminated in the panel. It is this neutral that you need for 120 volt connections. You didn't state how many panel slots there are in the panel. If you are able install a 15 amp breaker into the panel and connect the wires going to the load. The black wire will go to the breaker and the white wire will go to the neutral bar in the panel.


What size ground wire needed for a 200amp service panel in new jersey?

#6 bare copper wire.


Can you crimp copper grounding electrode to aluminum neutral of service entrance?

You should not have to crimp the copper grounding electrical wire to the aluminium service neutral. There is only one place where these two wires should meet. In the service distribution panel there is a neutral block where the two wires are connected. There are individual terminal points in the block. Tighten the ground rod wire under one of these points and place the incoming service neutral under another point in the same block. In this same block there will be a machine screw that bonds the neutral block to the distribution panel's enclosure.