Hire an electrician. Do not install your main service yourself. It must meet code, it must follow many regulations to the letter, it must be inspected, and it must be done my a licenced professional. You will not save money by trying to do it yourself, and it is illegal. Chances are your power company will not connect service if it is not installed by a licenced professional.

User Avatar

Wiki User

17y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

4mo ago

For a 200 amp panel with a 250 ft run, you would typically need to use 3/0 AWG copper wire or 250 kcmil aluminum wire to ensure safe and efficient power distribution. It is recommended to consult with a qualified electrician to determine the exact wire size required based on the specific conditions of your installation.

This answer is:
User Avatar

User Avatar

Wiki User

10y ago

Use 3/0 copper.

<<>>

To over come the voltage drop and maintain a full 200 amps at the load end, a 250 MCM copper conductor will limit the voltage drop to 3% or less when supplying 200 amps for 250 feet on a 240 volt three wire system.

This answer is:
User Avatar

User Avatar

Wiki User

11y ago

AWG 0000 (4/0)

<<>>

A 250 MCM copper conductor with an insulation factor of 75 or 90 degrees C are rated at 255 and 265 amps respectively.

This answer is:
User Avatar

User Avatar

Wiki User

15y ago

1 1/4 inches

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What size wire needed for 250 run 200 amp panel?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

What size wire is needed to feed a 125 amp sub panel from a 200 amp panel less than 200 wire feet away?

For a 125 amp sub panel located less than 200 feet away from a 200 amp panel, you would typically use a 2 AWG copper wire or 1/0 AWG aluminum wire to safely carry the current load. It's important to follow local electrical codes and regulations when selecting the wire size.


Ground wire size for 200?

The size of the ground wire for a circuit is typically based on the size of the circuit breaker protecting that circuit. For a 200 amp circuit breaker, the recommended ground wire size is 4/0 AWG (American Wire Gauge) copper wire. This wire size helps ensure that the ground wire can safely carry any fault currents that may occur in the electrical system.


Is neutral wire same size as hot in 200 amp panel?

Yes, in a residential 200 amp panel, the neutral wire is typically the same size as the hot wires. This is to ensure that the neutral wire can safely carry the same current as the hot wires and maintain proper balance in the electrical system. Always consult the National Electrical Code or a qualified electrician for specific requirements.


How do you know what wire is ground on 200 amp service?

In a 200 amp service panel, the ground wire is typically a bare copper wire or green insulated wire. It is connected to the ground bar within the panel. Make sure to consult the manufacturer's instructions or a licensed electrician for guidance specific to your installation.


What size grounding wire do you use as the 4th wire running in your conduit from your 200 amp meter box to your 200amp service panel this is the ground wire from box to box?

For a 200 amp service, you would typically use a 4/0 AWG copper wire for the grounding wire running between the meter box and the service panel. This size is suitable for carrying the necessary current and providing proper grounding protection for the electrical system.

Related questions

What size wire is needed to feed a 125 amp sub panel from a 200 amp panel less than 200 wire feet away?

For a 125 amp sub panel located less than 200 feet away from a 200 amp panel, you would typically use a 2 AWG copper wire or 1/0 AWG aluminum wire to safely carry the current load. It's important to follow local electrical codes and regulations when selecting the wire size.


What size neutral wire for 200 amp service panel?

AWG # 3/0 copper.


Ground wire size for 200?

The size of the ground wire for a circuit is typically based on the size of the circuit breaker protecting that circuit. For a 200 amp circuit breaker, the recommended ground wire size is 4/0 AWG (American Wire Gauge) copper wire. This wire size helps ensure that the ground wire can safely carry any fault currents that may occur in the electrical system.


Is neutral wire same size as hot in 200 amp panel?

Yes, in a residential 200 amp panel, the neutral wire is typically the same size as the hot wires. This is to ensure that the neutral wire can safely carry the same current as the hot wires and maintain proper balance in the electrical system. Always consult the National Electrical Code or a qualified electrician for specific requirements.


What size USE wire is needed for 200 amps?

As a service entrance wire you need AWG # 3/0 gauge copper.


What is the minimum service size for a 225amp residential service?

A 200 amp service panel with a 60 amp sub-panel.


How do you know what wire is ground on 200 amp service?

In a 200 amp service panel, the ground wire is typically a bare copper wire or green insulated wire. It is connected to the ground bar within the panel. Make sure to consult the manufacturer's instructions or a licensed electrician for guidance specific to your installation.


What size grounding wire do you use as the 4th wire running in your conduit from your 200 amp meter box to your 200amp service panel this is the ground wire from box to box?

For a 200 amp service, you would typically use a 4/0 AWG copper wire for the grounding wire running between the meter box and the service panel. This size is suitable for carrying the necessary current and providing proper grounding protection for the electrical system.


Can you use one ought copper wire size for common lead to a 200 amp service panel?

No, a 1/0 copper wire size is not sufficient for a 200 amp service panel. For a 200 amp service panel, you would typically need to use 3/0 copper wire size for the service entrance cable. It is important to consult with a qualified electrician to ensure proper sizing and safety.


Do you need to change the wire size going from 100 amp service to 150 amp service?

Yes, the wire size has to be increased. The existing 100 amp service will now probably have a #3 conductor with an insulation factor of 75 or 90 degrees C which is rated for 100 and 105 amps respectively. Increasing to a 150 amp service will use a #1/0 wire size. If you are thinking of an upgrade, skip the 150 amp service and go to a 200 amp panel. New homes are installing 200 amp 42 circuit panels. The extra cost is only reflected in the materials as the labour costs will be the same regardless whether a 150 amp or a 200 amp panel is installed. The wire size for a 200 amp panel is #3/0. With an insulation factor of 75 or 90 degrees C the rating is 200 or 210 amps respectively.


What size ground wire is needed for 200amp service pannel in Chicago?

200 amp service in chicago uses 3 aught.


What size of solar panels is needed to charge a 12v 150ah battery with hours sunlight 10?

200 Watt Panel