no, because it is depend on its current carrying capacity.

eg-if 25amp current flowing in the ckt then 30amp breaker don't protect the ckt but if it is cross the rated capacity then breaker works.

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Will a 30 amp breaker protect a 24 Range?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Can you plug an electric range into an outlet on a 30 amp breaker?

Most Electric Ranges are plugged into a 50 A breaker for good reason. When everything is turned on it will likely draw more than 30 A. The first step is to find the rating plate on your range and see the current rating. If great than 24 A you shouldn't use 30 A breaker. Make sure connection wire is sized for the correct amperage.


How many lights can run off a 15 amp breaker?

Depends on the wattage. For example a 60W incandescent bulb draws about 1/2 amp so you could have thirty. Since you typically de-rate to 80% of the value of the breaker it would be 24.


I have 100 amp breaker box I want to put a 60amp double pole breaker in and run 60 amp wire to me garage. Do the y make a 60 amp breaker box with more then 4 breaker slots. or can you run 60 amp wire?

Rated for exactly 60amps you will find limited breaker spaces due to the rating of the hardware used in it's construction and air circulation restrictions from the equivalent limited enclosure area. When rated at a determined amperage level it is required to construct the device based on the worse case possible scenario which includes a continuous running load. This will determine it's minimum standards according to local and national codes for hardware, room, spacing, and, layout. This does not limit you to only this size panel though. As long as you install the 60amp breaker first in your house panel anything installed down stream {from the load side of the 60amp breaker will be protected up to 60 amps. Therefore you are permitted to exceed those ratings and still remain within code because regardless of what your load is, it can not exceed 60 amps without tripping the breaker. You can install a 12/24 {12-full size or 24-half size [mini's]} 100amp panel for additional breaker spaces and the cost difference is negligible. One code issue to consider is if the sub panel in the garage is not in line of sight of that 60amp breaker then you might want to install another 60amp breaker in the garage panel to interrupt the incoming power giving you the ability to work on/in the garage panel without the possibility of someone re-energizing it mistakenly. I would suggest before this to consult with an electrician for a load calculation to determine if there is 60amps of available power in the 100amp panel in the home. This panel may not have an over-current 100amp main breaker which means it is possible to exceed the panel rating of this unprotected panel. Installing a 100amp over-current device {breaker, fused safety switch, fuse block etc...} like your 60 amp breaker to the garage it will limit the total load to only 100amps. Good Luck and obtain all permits and full understanding of the project and safety protocols in it's regards.


Can you plug equipment rated for 50A into a 30A circuit?

Yes, with a caveat. The 50A wire and plug is more than heavy enough for the dryer, so there is no problem there. The possible problem is that the dryer is designed to be protected by a 30A breaker. In the event of failure in the dryer, the breaker may not trip as it is oversized. The best solution? Get a small breaker box from a home center and mount a 30A breaker in it. Mount it on the back of the dryer, run the 50A cord into the feed lugs of the box, and connect the dryer feed to the 30A breaker. This way you can plug the dryer into the 50A outlet like you want, and the dryer is protected with a 30A breaker as usual. You can get small breaker boxes or fused disconnects without too much cost. Just make sure the breaker box / disconnect panel is rated to 50A, as you want to feed it off a 50A circuit. As long as the voltage requirement of the dryer matches the voltage of the outlet (which is presumably 240 volts), then yes. The amp rating of the cord and outlet is merely the maximun current (amps) allowed. You're well under that with 24 amps.


Do two 12 volt 100 amp hour batteries give me 200 amp hours at 24 volt?

No. If you connect two 12 volt batteries in series(positive to negative) to make 24 volts, you will have 100 amp hours. If you connect two 12 volt batteries in parallel(pos to pos, neg to neg) you will stay at 12 volts but have 200 amp hours

Related questions

What is a 30 amp circuit breaker used for?

A 30 amp circuit breaker is needed unless the load is a motor circuit, then it has to be sized to 250 percent of the motors full load amps. For 30A circuit is needed breaker 30*1.25=37.5 --> 40A. If load is lamp or heater, then use breaker of group A or B. If load is motor, then use breaker of groupC or D (very hard start) or special safe breaker for motor - with variable amp setpoint. See related link also. By code you are only allowed 80% of the rating of a breaker. So 30x80%=24amps. 24 amps is the MAX allowed on a 30 amp breaker. You would need a 40amp breaker for a 30 amp circuit. 40x80%=32. So you would want a double pole 40amp breaker.


Can you plug an electric range into an outlet on a 30 amp breaker?

Most Electric Ranges are plugged into a 50 A breaker for good reason. When everything is turned on it will likely draw more than 30 A. The first step is to find the rating plate on your range and see the current rating. If great than 24 A you shouldn't use 30 A breaker. Make sure connection wire is sized for the correct amperage.


How many lights can run off a 15 amp breaker?

Depends on the wattage. For example a 60W incandescent bulb draws about 1/2 amp so you could have thirty. Since you typically de-rate to 80% of the value of the breaker it would be 24.


What size breaker should be used for a 3.6 kW oven?

3000 / 240 = Amps. You de-rate a breaker by 20 % for continuous load like an oven. You could get by with a 20 Amp breaker and 12 AWG wire. However, I would recommend 30 Amps and 10 AWG for an oven for the long run.


Will a 24 volt 1.2 Amp charger charge the same as a 24 volt 1.5 Amp charger?

Yes, only it will take the 1.2 amp a little longer to fully charge a battery than a 1.5 amp charger.


What size amp circuit breaker should be used for a wall oven?

The electrical current requirements of a wall oven can vary, depending on the heating elements used by the manufacturer. To determine the current use, refer to either the operators manual, or the service tag. The service tag may list the power consumption in Watts, in which case you'll need to convert the watts to amps using the following formula: Amps = Watts/Volts Once you've determined the current draw in Amps, OVER-rate the breaker by 20%. For example, if you calculate that the oven draws exactly 20 amps, over-rate that to 24 amps, then use the next larger size breaker and wire that is appropriate to the breaker; typically that would mean a 10 AWG wire and 30 Amp breaker. BUT!!! If you have any questions, contact a licensed electrical professional.


Is 30 amp wire good enough to push a 220v welder?

If the welder does not list the input amperage, jyou can always refer back to the math that you learned in school. A simple algebraic formula will help you figure out the amperage: Amps * Volts = Watts Since you already know the Volts (use 240 for calculation), you should be able to calculate the amperage that is used by the welder. Up to about 12 Amps, use a 15 amp breaker and 14 AWG wire. Up to about 16 Amps, use a 20 amp breaker and a 12 AWG wire. Up to about 24 Amps, use a 30 amp breaker and a 10 AWG wire. You should have a qualified electrical professional perform any wiring changes if you do not have an adequate circuit already available to where you will be using the welder.


What is the range of 30 and 52 and 24?

The range of 30, 52 and 24 is 52 - 24 = 28


What are the release dates for Breaker High - 1997 Tamira Has Two Faces 1-24?

Breaker High - 1997 Tamira Has Two Faces 1-24 was released on: USA: 10 November 1997


What gauge wire for 24 amp fuses?

AWG # 10


I have 100 amp breaker box I want to put a 60amp double pole breaker in and run 60 amp wire to me garage. Do the y make a 60 amp breaker box with more then 4 breaker slots. or can you run 60 amp wire?

Rated for exactly 60amps you will find limited breaker spaces due to the rating of the hardware used in it's construction and air circulation restrictions from the equivalent limited enclosure area. When rated at a determined amperage level it is required to construct the device based on the worse case possible scenario which includes a continuous running load. This will determine it's minimum standards according to local and national codes for hardware, room, spacing, and, layout. This does not limit you to only this size panel though. As long as you install the 60amp breaker first in your house panel anything installed down stream {from the load side of the 60amp breaker will be protected up to 60 amps. Therefore you are permitted to exceed those ratings and still remain within code because regardless of what your load is, it can not exceed 60 amps without tripping the breaker. You can install a 12/24 {12-full size or 24-half size [mini's]} 100amp panel for additional breaker spaces and the cost difference is negligible. One code issue to consider is if the sub panel in the garage is not in line of sight of that 60amp breaker then you might want to install another 60amp breaker in the garage panel to interrupt the incoming power giving you the ability to work on/in the garage panel without the possibility of someone re-energizing it mistakenly. I would suggest before this to consult with an electrician for a load calculation to determine if there is 60amps of available power in the 100amp panel in the home. This panel may not have an over-current 100amp main breaker which means it is possible to exceed the panel rating of this unprotected panel. Installing a 100amp over-current device {breaker, fused safety switch, fuse block etc...} like your 60 amp breaker to the garage it will limit the total load to only 100amps. Good Luck and obtain all permits and full understanding of the project and safety protocols in it's regards.


What is the range 86 24 52 36 98?

Range = 98 - 24 = 74