∙ 7y agoThere are two things to think about here.
First of all a 200 amp breaker will not physically fit into a 100 amp panel. This is so designed because the panel buss is not designed to conduct 200 amps before the current is cut off. A 100 amp rating on the panel is the maximum amount of current that the manufacturer states, that can be handled safely.
Second if the 200 amp breaker is in the main panel then everything downstream from that breaker has to be rated for 200 amp conductivity. The wire size will have to be 3/0 from the breaker to the first over current device in the sub panel which will be the sub panel's main breaker. The sub panel can not be a load center but will have to be a combination panel. I doubt that the 100 amp sub panel's main breaker lugs would be large enough to connect the 3/0 cable.
Wiki User
∙ 7y agoFor a circuit with a load of 10 amps, a breaker of 15 amps should be used for adequate protection. It is important to choose a breaker size that is slightly higher than the load to prevent frequent tripping and ensure safety.
No, panel breakers are designed to fit specifically in the panel they are made for. Using a breaker from one manufacturer in a different panel could lead to compatibility issues, safety hazards, and potentially void warranties. It is always best to use breakers that are compatible with the specific panel being used.
The biggest circuit breaker in any home is the main breaker located in your main breaker panel that is installed where your electrical service cable comes into your home.
It is not recommended to use a 40 amp breaker to feed a sub panel, as the breaker size should be based on the size of the wire and the load of the sub panel. It is important to follow the manufacturer's guidelines and local electrical codes when determining the appropriate breaker size for a sub panel.
It depends on your local building code.
In a residential application it would most likely be used as the breaker for the entire main electric panel or a subpanel feed.
For a circuit with a load of 10 amps, a breaker of 15 amps should be used for adequate protection. It is important to choose a breaker size that is slightly higher than the load to prevent frequent tripping and ensure safety.
For a 100 Amp breaker panel it would be 2 AWG. For 150 Amps it would require 2/0 (2 ought) aluminum wire.
You can. Using these size breakers in a 60 amp sub panel might be pushing the limit for breaking the sub panels feeder breaker. The breaker feeding the sub panel will have to be no bigger than 60 amps because of the main bus bar capacity of the sub panel. It would be better to install a 100 amp sub panel and then there would be a bit of a buffer and you will have the ability to add additional small load circuits.
In North America a two pole breaker will be used in the distribution panel for a supply of 240 volts for a 240 volt load.
No, panel breakers are designed to fit specifically in the panel they are made for. Using a breaker from one manufacturer in a different panel could lead to compatibility issues, safety hazards, and potentially void warranties. It is always best to use breakers that are compatible with the specific panel being used.
Not exactly sure what your question is and you need to make sure you are in compliance with electrical code for your jurisdiction. But, generally speaking you install a large breaker (let's say 100A 2 pole breaker to power the sub panel) just as you would install any other breaker in the presently used (hot) panel, and the proper sized cable then goes from old to new and terminates on the main lugs of the new panel. Ground and neutral are usually isolated from each other in the sub panel but depends on other factors as to location of the sub panel, etc.
The biggest circuit breaker in any home is the main breaker located in your main breaker panel that is installed where your electrical service cable comes into your home.
It depends on your local building code.
It is not recommended to use a 40 amp breaker to feed a sub panel, as the breaker size should be based on the size of the wire and the load of the sub panel. It is important to follow the manufacturer's guidelines and local electrical codes when determining the appropriate breaker size for a sub panel.
I know what would happen. The three amp fuse would blow. Any device that is plugged into a receptacle with out having sufficient resistance to limit the current flow will dead short the circuit and cause the breaker that feeds the circuit to trip. In this case the fuse being of a lower rating that the feed breaker the fuse will blow without tripping the receptacle's feed breaker.
No, a Meter Main Combo typically includes the main breaker as part of its design, so you would not need an additional main breaker in the panel. The main breaker in the Meter Main Combo serves as the disconnect for the panel.