The grounding system of a distribution must be from zero ohms to a maximum of two ohms. This is usually obtained by bonding all metallic parts back to the distribution centre with a wire capable of handling the circuits fault current if the circuit should ground out. The ground wire in cable sets is used for this purpose.

User Avatar

Wiki User

9y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: When grounding a metal box what must be done?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

What is a strap or yoke on a duplex grounding receptacle?

The yoke or strap is the metal fram that hold everything together and where the outlet attaches to the box.


Is it necessary to ground at all metal junction boxes when using metal conduit or cable?

In a completely metallic conduit system it is not necessary to ground each junction box as long as the metallic system has the grounding capacity rating larger than that of the over current device protecting the circuit. The code book states what size conduits are rated at, for grounding amperages.


Where do you connect the bare ground wire?

Usually there is inside the fuse box a metal bolt and nut provided or a rail in case the box itself is made out of plasic. Typically there is a sticker with the earting symbol next to it(http://www.kpsec.freeuk.com/symbol.htm) Join the green/yellow cable to that one, or the color used in your country


How do you Ground a 3 wire service?

If you do not have a underground metal water pipe coming into the building then you put a ground rod at least 2 feet from the buildingf into the ground attach one end of the wire to ground rod run your ground wire and attach the other end to the neautral bar in the panel box. You need special transformer called as grounding transformer for this purpose. Grounding transformer is basically Wye-Delta type transformer with Wye connected winding connected to 3 line wires and derived neutral from Wye side grounded through desired grounding device. Delta side winding of grounding transformer is kept at no load.


Where do you hook the ground wire on a porcelain light fixture on a metal box?

Connect the ground wire to the metal box.

Related questions

When a conductor cable enters a metal box what must be done in each box for NEC code to be met?

NEC code 314.40(D) requires that all metal boxes have provisions for the attachment of equipment grounding conductor. In other words all metal boxes must be grounded to meet code.


How do you ground your meter box to your breaker box?

The grounding is done through the metal nipple that connects out of the back of the meter base and into the back of the breaker panel.


Do light fittings need to be earthed?

Normally the fixtures come with a grounding screw that you attach the grounding wire to. If the box you attaching the fixture to is metal and there is no grounding wire present then the grounded conduit should ground you fixture.


Does a plastic outlet box need to be grounded?

yes the device must be grounded per NEC code. if the juncrion box is metal you must also sufficiently ground the box using a ground screw or clip. the ground box should be uninterrupted if the device is removed. (the device screws mounted to the box is not a suitable grounding means.


How do you you change a two wire recepial without a ground to a two wire with a ground?

Shut the power off to the recepticle. Then take apart the old outlet. Wire up the new outlet. The only difference between the old and the new will be the grounding. If BX armour cable is used, then you will need to take a jumper wire from the grounding nut on the outlet and connect it to the box with a grounding screw. This wire must be green. If romex has been used, then there is a gounding wire that is in the bundle of the wires coming into the box. If it a metal box, then you must use a grounding screw and ground that wire to the boc and then connect that same wire to the outlet. If its a plastic box, then just wire the ground to the outlet. I also like to wrap the outlet in electrical tape, just incase the the wires were to come loose, they would note hit against the box shorting out. Finally, put the pieces back together. And your DONE!


What is a strap or yoke on a duplex grounding receptacle?

The yoke or strap is the metal fram that hold everything together and where the outlet attaches to the box.


On a duplex grounding type receptacle what is strap or yoke?

The yoke or strap is the metal fram that hold everything together and where the outlet attaches to the box.


What is the difference between grounding and bonding?

Grounding is a direct path (that is, a wire, usually green) from the electrical outlet or switch back to the service panel, which sends stray current back to the service panel and then to the power plant along with the normal alternating current. This gives stray current a means to return to earth (which is what all electricity wants to do). If this path were not available, stray current would remain static until a pathway showed up (like, your finger, which would result in a shock). So, grounding protects you from dangerous shocks. Bonding is connecting any metal or electrically conductive material to a grounding wire. An electrical outlet is attached to a metal box. A grounding wire is connected to the outlet. Its purpose is to return stray current from any device plugged into the outlet--like a toaster--back to the service panel. Connecting the metal box that contains the outlet to the outlet's grounding wire also grounds the box, so touching the box doesn't give you a shock. The connection is made with a wire screwed to the box, then connected to the green wire grounding the switch or outlet.


I purchased a light from IKEA but it does not have anywhere for the earth wire to go How should I wire it up Thanks in advance?

If the fixture doesn't have a ground wire attached or a grounding screw, then it doe not require to be grounded . It likely has insulated parts between the base where it attaches to the box and the lampholder. Simply shunt or cap the incoming ground wire with a wire nut. If you're mounting the fixture to a metal box , then attach the incoming ground wire to the box with a grounding clip or screw in the inside back of the metal box.


Is it safe to glue or tape an electrical socket in place?

No, the receptacle needs the screws in place to complete the bond between the metal component of the receptacle to the metal component in the receptacle's junction box. This bond is entirely separate from the grounding of the receptacle.


Is it necessary to ground at all metal junction boxes when using metal conduit or cable?

In a completely metallic conduit system it is not necessary to ground each junction box as long as the metallic system has the grounding capacity rating larger than that of the over current device protecting the circuit. The code book states what size conduits are rated at, for grounding amperages.


How do you ground a plastic box ground wire attached to GCFI and ground at fuse panel. Do I need to ground at the box itself as well?

Grounding a plastic box is a little hard as plastic is a nonconductor.be satisfied with grounding to a ground wire.